FS65ACC חיישני רעידות ותאוצה
FS65ACC מתאים למדידת תאוצה בתדרים נמוכים באלמנטים גמישים כגון כבלי גשרים. הוא מתחבר בבורג הרכבה ונקרא באמצעות יחידת קריאה אופטית (interrogator). לאיסוף רב־צירי אפשר לשלב כמה חיישנים בכיווני התקנה שונים.
לאתר של HBK (נפתח בלשונית חדשה)
הדגמים בסדרה
עמודה לכל דגם: מה שונה בין דגמי הסדרה.
| פרמטר | 1-FS65ACC-10/1530 | 1-FS65ACC-10/1540 | 1-FS65ACC-10/1550 | 1-FS65ACC-10/1560 | 1-FS65ACC-10/1570 | K-FS65ACC |
|---|---|---|---|---|---|---|
| טמפרטורת עבודה | -23–85 °C | -23–85 °C | -23–85 °C | -23–85 °C | -23–85 °C | -23–85 °C |
| בסיס קצב הדגימה | Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. | Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. | Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. | Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. | Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. | Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. |
| מגבלת קצב בגלל קריאת המערכת | True | True | True | True | True | True |
| מספר ערוצי מדידה | 1 | 1 | 1 | 1 | 1 | 1 |
| יציאות וממשקים | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| יכולת מדידת תאוצה סטטית DC | False | False | False | False | False | False |
| פרטי מפרט טכני | ±10 g indexed capacity; Uniaxial; General purpose; Center bolt mounting | ±10 g indexed capacity; Uniaxial; General purpose; Center bolt mounting | ±10 g indexed capacity; Uniaxial; General purpose; Center bolt mounting | ±10 g indexed capacity; Uniaxial; General purpose; Center bolt mounting | ±10 g indexed capacity; Uniaxial; General purpose; Center bolt mounting | ±10 g indexed capacity; Uniaxial; General purpose; Center bolt mounting |
| תחום תדרי תגובה | 0–300 Hz | 0–300 Hz | 0–300 Hz | 0–300 Hz | 0–300 Hz | 0–300 Hz |
| מספר צירי מדידה | 1 | 1 | 1 | 1 | 1 | 1 |
| בסיס הגדרת לינאריות | No numeric sensitivity tolerance was exposed for this ordering code in the official index. | No numeric sensitivity tolerance was exposed for this ordering code in the official index. | No numeric sensitivity tolerance was exposed for this ordering code in the official index. | No numeric sensitivity tolerance was exposed for this ordering code in the official index. | No numeric sensitivity tolerance was exposed for this ordering code in the official index. | No numeric sensitivity tolerance was exposed for this ordering code in the official index. |
| בסיס הגדרת חזרתיות | HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. | HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. | HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. | HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. | HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. | HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. |
| יציאת חיישן רעידות | Fiber Bragg Grating; Analogue | Fiber Bragg Grating; Analogue | Fiber Bragg Grating; Analogue | Fiber Bragg Grating; Analogue | Fiber Bragg Grating; Analogue | Fiber Bragg Grating; Analogue |
| רגישות מתח לתאוצה | 59 mV/g | 59 mV/g | 59 mV/g | 59 mV/g | 59 mV/g | 59 mV/g |
| סטטוס | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל |
התעשיות שאנו משרתים
שאלות נפוצות
תשובות לשאלות הנפוצות ביותר על המוצרים והשירותים שלנו
טווח התאוצה הוא ±10 g ותחום התדר המוצהר הוא 0–50 Hz.
הרגישות הטיפוסית היא 59 pm/g. זהו שינוי אורך הגל ביחס לתאוצה.
גוף החיישן מתחבר בבורג M5. מיישרים את כיוון המדידה המסומן לפי ציר התאוצה שנדרש לבדוק.
לכל חיישן ציר אחד. מודדים בשלושה צירים באמצעות שלושה חיישנים בכיוונים מאונכים ובמערך קריאה שמאפשר לקלוט את שלוש המדידות.
גיליון הנתונים מציין השפעת טמפרטורה צולבת טיפוסית של 0.4 g/°C. בדקו את תרומתה למדידה, במיוחד כשמחפשים תאוצות קטנות או תדרים קרובים לאפס.