Skip to content

4954-A

From the B&K measurement microphone sets series

HBK measurement microphone sets combine a microphone cartridge with a preamplifier. Select a model according to frequency range and sound pressure level.

Frequency response
3–80000 Hz
Microphone sensitivity
2.8 mV/Pa
Maximum SPL
159 dB SPL
Sound field
Free field / outdoor
Visit the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for 4954-A
Microphone diameter 0.25 inch
Sound field Free field / outdoor
Microphone sensitivity 2.8 mV/Pa
Maximum SPL 159 dB SPL
Acoustic standard IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration
Operating temperature -20–80 °C

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Frequency response 3–80000 Hz
Frequency response 16–80000 Hz
Microphone polarization CCLD
Microphone polarization Prepolarized