The MXFS reads wavelength changes from FBG sensors and integrates optical measurements into a QuantumX system. Choose a static or dynamic version for the required rate and sensor count per fiber. Verify capacity, connector type and reading rate for the selected variant and sensor layout.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of QuantumX MXFS
ADC sampling rate 10–2000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of QuantumX MXFS compared by parameter
Parameter 1-MXFS8DI1/FC 1-MXFS8DI1/SC 1-MXFS8SI1/FC 1-MXFS8SI1/SC
Protection class (DIN EN 60529) IP20 IP20 IP20 IP20
Technical specification details Inputs: Fiber Bragg grating; Outputs: None; Housing: Frame, Rack with PC, Standalone; Interfaces: TCP/IP, Firewire Inputs: Fiber Bragg grating; Outputs: None; Housing: Frame, Rack with PC, Standalone; Interfaces: TCP/IP, Firewire Inputs: Fiber Bragg grating; Outputs: None; Housing: Frame, Rack with PC, Standalone; Interfaces: TCP/IP, Firewire Inputs: Fiber Bragg grating; Outputs: None; Housing: Frame, Rack with PC, Standalone; Interfaces: TCP/IP, Firewire
Interfaces Ethernet Ethernet Ethernet Ethernet
ADC sampling rate 2000 samples/s 2000 samples/s 10 samples/s 10 samples/s
Number of measurement channels 8 8 8 8
Status Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It reads Fiber Bragg Grating (FBG) sensors. With the appropriate sensor configuration, wavelength shifts can be converted into strain, temperature or another supported quantity.

The MXFS8 has eight fiber connectors. Multiple FBG sensors can share a fiber. The channel count per connector depends on the variant and wavelength plan.

HBK lists 100 or 2,000 samples/s for dynamic acquisition and 1 or 10 samples/s for static acquisition. Check the modes available on the exact order code.

The published optical range is 1,500–1,600 nm. Plan the sensor wavelengths and operating separation between their peaks.

The manufacturer lists FC/APC and SC/APC configurations. Match the connector to the module order code and the installed fiber chain.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words