DT6222
From the capaNCDT DT62xx controllers series
capaNCDT DT62xx controllers: measurement controllers by Micro-Epsilon for capacitive.
- Number of measurement channels
- 4
Technical specification
Every engineering figure, laid out to scan quickly
| Linearity (% FSO) | 0.1 % |
|---|---|
| Interfaces | Ethernet |
| Output update rate | 3.906 kHz |
| Number of measurement channels | 4 |
| Storage temperature | -10–75 °C |
| Operating temperature | 10–60 °C |
| Protection class (DIN EN 60529) | IP40 |
| Frequency response cutoff Maximum rate with a compatible controller | 20 kHz (−3 dB) |
| Channels | Up to 4 inputs; one module per sensor head |
| Analog output | 0–10 V / 4–20 mA; select output path |
| Static resolution (% FSO) | 0.0005 % FSO (RMS; 2 Hz; end-of-range reference) |
| Dynamic resolution (% FSO) | 0.05 % FSO (RMS; 20 kHz) |
| Module slots | 4 |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Dimension (drawing reference) | 75 mm |
|---|---|
| Dimension (drawing reference) | 100 mm |
| Dimension (drawing reference) | 125 mm |
| Dimension (drawing reference) | 150 mm |
| Dimension (drawing reference) | 90 mm |
Compatible system components
Accessories
-
DL6222
- Measuring rate
- Not specified
- Communication
- Not specified
- Inputs
- 1
- Signal type
- Not specified
- Bandwidth (−3 dB)
- 20 kHz
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Use the DT6222 basic module and DL6222 demodulators for up to 4 measuring channels. Supported channel count does not mean that all modules are included. Each channel also needs a suitable sensor head and cable.
No. The 20 kHz value is the bandwidth at −3 dB. The table lists a maximum digital measuring rate of 3.906 kHz. Using that bandwidth through an analogue output requires a suitable DAQ and an assessment of the complete measurement chain.
The manufacturer lists ±0.1% FSO linearity for the controller with DL6222. This is not the combined sensor-and-controller linearity; the manufacturer requires adding the sensor contribution on the same range basis.
The specification lists Ethernet and IP40 protection. Analogue 0–10 V and 4–20 mA outputs are listed separately. Select the acquisition path explicitly; an analogue connection does not make the output EtherCAT or PROFINET.
Get a quote or advice
Tell us what you need and an engineer will come back to you.