Technical specification for IFC2422
Linearity (% FSO) Typical linearity < ±0.02% FSO; depends on sensor
Measuring rate 10 kHz
Layers in multi-peak measurement 1 layer
Power consumption 10 W
Number of measurement channels 2
Storage temperature -20–70 °C
Operating temperature 5–50 °C
Protection class (DIN EN 60529) IP40
Weight 2.25 kg
Controller operation and indicators Multifunction button for adjustable functions and factory reset after 10 s; five LEDs for intensity, range, status and supply voltage.
Permissible ambient light 30,000 lx
Adjustable measuring rate range 100–10000 Hz
Controller light source Internal white LED
Characteristic curves per channel up to 20 characteristic curves for different sensors per channel, selected via menu table
Controller synchronisation yes
Controller electrical connection 3-pin supply terminal strip; 15-pin HD-sub encoder connection (max. 3 m, 30 m with external encoder supply); 9-pin Sub-D RS422 (max. 30 m); 3-pin output terminal strip (max. 30 m); 11-pin I/O terminal strip (max. 30 m); RJ45 Ethernet out/EtherCAT in-out (max. 100 m)
Controller housing material Aluminum
Controller mounting free-standing, DIN rail mounting
Controller indicators Web interface; multifunction button; indicator LEDs (source table differs by family)
Analog output resolution 16 bit, teachable
RS422 output resolution 18 bit
Ethernet output resolution 1 nm; interface encoding resolution, not sensor accuracy
Channels 2
Analog output Voltage 0–10 V; current 4–20 mA
Signal type Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
Measuring range versus measuring rate Full measuring range through 8 kHz. At 9–10 kHz: sensor-dependent, up to 80% FSO; exact window must be verified for the selected sensor. The available window between 8 and 9 kHz is not specified. Both IFC2422 channels retain the full measuring rate.
Rate and interface conditions EtherCAT SYNC0: the manual documents a 153846–10000000 ns cycle (nominal 6.5–0.1 kHz), subject to matching controller revision. FreeRun requires the measurement counter to identify fresh values. Video via SDO changes process-data updates to image-triggered updates. Output reduction affects only selected interfaces; a held error-time value is not a new measurement.
RS422 output settings RS422 binary, 8N1. Factory setting 115.2 kBd, configurable up to 4 MBd. Output depends on the selected signals and output settings.

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces EtherCAT
Interfaces Ethernet
Interfaces RS422