IFC2422
From the confocalDT IFC24xx controllers series
Confocal controllers process signals from compatible sensor heads for distance and thickness measurement.
- Number of measurement channels
- 2
Technical specification
Every engineering figure, laid out to scan quickly
| Linearity (% FSO) | Typical linearity < ±0.02% FSO; depends on sensor |
|---|---|
| Measuring rate | 10 kHz |
| Layers in multi-peak measurement | 1 layer |
| Power consumption | 10 W |
| Number of measurement channels | 2 |
| Storage temperature | -20–70 °C |
| Operating temperature | 5–50 °C |
| Protection class (DIN EN 60529) | IP40 |
| Weight | 2.25 kg |
| Controller operation and indicators | Multifunction button for adjustable functions and factory reset after 10 s; five LEDs for intensity, range, status and supply voltage. |
| Permissible ambient light | 30,000 lx |
| Adjustable measuring rate range | 100–10000 Hz |
| Controller light source | Internal white LED |
| Characteristic curves per channel | up to 20 characteristic curves for different sensors per channel, selected via menu table |
| Controller synchronisation | yes |
| Controller electrical connection | 3-pin supply terminal strip; 15-pin HD-sub encoder connection (max. 3 m, 30 m with external encoder supply); 9-pin Sub-D RS422 (max. 30 m); 3-pin output terminal strip (max. 30 m); 11-pin I/O terminal strip (max. 30 m); RJ45 Ethernet out/EtherCAT in-out (max. 100 m) |
| Controller housing material | Aluminum |
| Controller mounting | free-standing, DIN rail mounting |
| Controller indicators | Web interface; multifunction button; indicator LEDs (source table differs by family) |
| Analog output resolution | 16 bit, teachable |
| RS422 output resolution | 18 bit |
| Ethernet output resolution | 1 nm; interface encoding resolution, not sensor accuracy |
| Channels | 2 |
| Analog output | Voltage 0–10 V; current 4–20 mA |
| Signal type | Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet) |
| Measuring range versus measuring rate | Full measuring range through 8 kHz. At 9–10 kHz: sensor-dependent, up to 80% FSO; exact window must be verified for the selected sensor. The available window between 8 and 9 kHz is not specified. Both IFC2422 channels retain the full measuring rate. |
| Rate and interface conditions | EtherCAT SYNC0: the manual documents a 153846–10000000 ns cycle (nominal 6.5–0.1 kHz), subject to matching controller revision. FreeRun requires the measurement counter to identify fresh values. Video via SDO changes process-data updates to image-triggered updates. Output reduction affects only selected interfaces; a held error-time value is not a new measurement. |
| RS422 output settings | RS422 binary, 8N1. Factory setting 115.2 kBd, configurable up to 4 MBd. Output depends on the selected signals and output settings. |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Interfaces | EtherCAT |
|---|---|
| Interfaces | Ethernet |
| Interfaces | RS422 |
The industries we serve