ILD1900-500
From the optoNCDT 1900 series
Laser triangulation sensors with an integrated controller and IP67 housing. ASC surface compensation and exposure control support measurements on surfaces with changing reflectivity.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 500 mm |
|---|---|
| Start of measuring range | 100 mm |
| End of measuring range | 600 mm |
| Working distance | 100–600 mm |
| Linearity | 400 µm |
| Interfaces | Ethernet |
| Operating temperature | 0–50 °C |
| Protection class (DIN EN 60529) | IP67 |
| Light spot width X | 0.95 mm |
| Light spot width Y | 1.2 mm |
| Contact | Non-contact |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Outputs and interfaces | Digital I/O |
|---|---|
| Outputs and interfaces | Analog 0-10V |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.