Skip to content

C11 Force

Subminiature strain-gauge button transducer for compression in tight spaces at temperatures up to 120 °C. Passive mV/V output and IP64 protection.

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C11
Force range 0–2000 N
ADC sampling rate 450–40000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of C11 compared by parameter
Parameter 1-C11/100N-3 1-C11/1KN-3 1-C11/200N-3 1-C11/2KN-3 1-C11/500N-3 1-C11/50N-3 C11-1000N C11-100N C11-2000N C11-200N C11-500N C11-50N
Load mode Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only
Protection class (DIN EN 60529) IP64 IP64 IP64 IP64 IP64 IP64 IP64 IP64 IP64 IP64 IP64 IP64
Sampling rate limited by system readout True True True True True True Not specified Not specified Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified
Force range 0–100 N 0–1000 N 0–200 N 0–2000 N 0–500 N 0–50 N 0–1000 N 0–100 N 0–2000 N 0–200 N 0–500 N 0–50 N
Technical specification details Maximum capacity (nominal load): 100 N; Height (without accessories): 0.16 in; Diameter (without cable or plug): 0.3937 in Maximum capacity (nominal load): 1 kN; Height (without accessories): 0.28 in; Diameter (without cable or plug): 0.62992 in Maximum capacity (nominal load): 200 N; Height (without accessories): 0.16 in; Diameter (without cable or plug): 0.3937 in Maximum capacity (nominal load): 2 kN; Height (without accessories): 0.28 in; Diameter (without cable or plug): 0.62992 in Maximum capacity (nominal load): 500 N; Height (without accessories): 0.28 in; Diameter (without cable or plug): 0.62992 in Maximum capacity (nominal load): 50 N; Height (without accessories): 0.16 in; Diameter (without cable or plug): 0.3937 in 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression 100 N rated capacity = 100 N (10.1972 kg mass equivalent at standard gravity); compression 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression 200 N rated capacity = 200 N (20.3943 kg mass equivalent at standard gravity); compression 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression 50 N rated capacity = 50 N (5.0986 kg mass equivalent at standard gravity); compression
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown RS422 / RS485 Analog 0-10V RS422 / RS485 Digital I/O Analog 0-10V Digital I/O
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
Accuracy class 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
Numeric manufacturer accuracy class 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Ethernet Ethernet PROFINET Ethernet Ethernet Ethernet
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified 19200 samples/s 40000 samples/s 450 samples/s 450 samples/s 40000 samples/s 450 samples/s
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 %
Status Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-C11/100N-3 (opens in a new tab) PDF — 1-C11/1KN-3 (opens in a new tab) PDF — 1-C11/200N-3 (opens in a new tab) PDF — 1-C11/2KN-3 (opens in a new tab) PDF — 1-C11/500N-3 (opens in a new tab) PDF — 1-C11/50N-3 (opens in a new tab) PDF — C11-1000N (opens in a new tab) PDF — C11-100N (opens in a new tab) PDF — C11-2000N (opens in a new tab) PDF — C11-200N (opens in a new tab) PDF — C11-500N (opens in a new tab) PDF — C11-50N (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. C11 is specified for compression. Apply force through its upper load button.

No. The specified height is 4 mm for 50–200 N capacities and 7 mm from 500 N. Select dimensions by capacity.

Yes. Strain gauges allow static measurement, while its high stiffness also supports rapidly changing forces.

The manufacturer specifies −20°C to +120°C for C11.

No. The data sheet specifies a nominal range of −20 to +100 °C and an operating range of −20 to +120 °C. Check temperature errors and accuracy conditions for the application rather than treating the operating limit as an identical accuracy guarantee throughout.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words