Skip to content

C15 Force

Strain-gauge reference transducer for compression calibration. IP67 protection and mV/V output for a suitable amplifier.

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C15
Force range 0–1000000 N
ADC sampling rate 450–40000 samples/s
Numeric manufacturer accuracy class 0.03–0.06

Models in the series

One column per model: what differs between the models of the series.

Models of C15 compared by parameter
Parameter C15 C15-1000kN C15-100kN C15-10kN C15-250kN C15-25kN C15-2p5kN C15-500kN C15-50kN C15-5kN
Load mode Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Sampling rate reference Use the exact configured transducer and HBK interface datasheets. MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
Linearity reference Family-level fallback: no unsupported scalar accuracy is added. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Outputs and interfaces Unknown RS422 / RS485 RS422 / RS485 RS422 / RS485 Analog 0-10V Analog 0-10V Digital I/O Digital I/O Digital I/O Digital I/O
Sampling rate limited by system readout True Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Configurable family; exact public ordering-code table not exposed on the current HBK page. 1000 kN rated capacity = 1,000 kN (101.9716 t mass equivalent at standard gravity); compression 100 kN rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression 10 kN rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression 250 kN rated capacity = 250 kN (25.4929 t mass equivalent at standard gravity); compression 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression 2.5 kN rated capacity = 2.5 kN (254.9291 kg mass equivalent at standard gravity); compression 500 kN rated capacity = 500 kN (50.9858 t mass equivalent at standard gravity); compression 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression
Repeatability reference Family-level fallback: verify the ordered model and calibration certificate. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Force range Not specified 0–1000000 N 0–100000 N 0–10000 N 0–250000 N 0–25000 N 0–2500 N 0–500000 N 0–50000 N 0–5000 N
Interfaces Not specified EtherCAT Ethernet EtherCAT Ethernet Ethernet Ethernet PROFINET Ethernet Ethernet
Accuracy (% FSO) Not specified 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 %
ADC sampling rate Not specified 19200 samples/s 19200 samples/s 19200 samples/s 40000 samples/s 19200 samples/s 19200 samples/s 19200 samples/s 450 samples/s 450 samples/s
Accuracy class Not specified ⁦0.06%⁩ ⁦0.04%⁩ ⁦0.03%⁩ ⁦0.05%⁩ ⁦0.04%⁩ ⁦0.03%⁩ ⁦0.05%⁩ ⁦0.04%⁩ ⁦0.03%⁩
Numeric manufacturer accuracy class Not specified 0.06 0.04 0.03 0.05 0.04 0.03 0.05 0.04 0.03
Status Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — C15 (opens in a new tab) PDF — C15-1000kN (opens in a new tab) PDF — C15-100kN (opens in a new tab) PDF — C15-10kN (opens in a new tab) PDF — C15-250kN (opens in a new tab) PDF — C15-25kN (opens in a new tab) PDF — C15-2p5kN (opens in a new tab) PDF — C15-500kN (opens in a new tab) PDF — C15-50kN (opens in a new tab) PDF — C15-5kN (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

ISO 376 Class 00 is specified from 10% to 100% of nominal force. It is a classification, not a zero-percent error claim.

C15 is intended for compression. The manufacturer identifies U15 for tensile and compressive reference measurements.

No. Output above 4 mV/V is specified from 25 kN, and rated-output adjustment is available as an option.

Yes. Measurement-chain calibration is available on request, rather than only calibrating the transducer separately.

The manufacturer specifies IP67 and a hermetically welded construction for C15.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words