C18 Force
Reference compression force transducer for calibration up to 5 MN. Rated IP68 for use with reference measurement rigs and in calibration laboratories.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–5000000 N |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-C18/100KN | 1-C18/10KN | 1-C18/1MN | 1-C18/200KN | 1-C18/20KN | 1-C18/2MN | 1-C18/300KN | 1-C18/3MN | 1-C18/500KN | 1-C18/50KN | 1-C18/5MN | C18-10kN | C18-5000kN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only |
| Protection class (DIN EN 60529) | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified |
| Technical specification details | Maximum capacity (nominal load): 100 kN; Calibration: Calibrated; Height (without accessories): 3.5 in; Diameter (without cable or plug): 2.95 in | Maximum capacity (nominal load): 10 kN; Calibration: Fulfills ISO 376; Height (without accessories): 2.83 in; Diameter (without cable or plug): 2.76 in | Maximum capacity (nominal load): 1 MN; Calibration: Calibrated; Height (without accessories): 6.73 in; Diameter (without cable or plug): 5.91 in | Maximum capacity (nominal load): 200 kN; Calibration: Calibrated; Height (without accessories): 3.5 in; Diameter (without cable or plug): 2.95 in | Maximum capacity (nominal load): 20 kN; Calibration: Calibrated; Height (without accessories): 2.83 in; Diameter (without cable or plug): 2.76 in | Maximum capacity (nominal load): 2 MN; Calibration: Calibrated; Height (without accessories): 9.41 in; Diameter (without cable or plug): 9.06 in | Maximum capacity (nominal load): 300 kN; Calibration: Calibrated; Height (without accessories): 4.41 in; Diameter (without cable or plug): 3.74 in | Maximum capacity (nominal load): 3 MN; Calibration: Calibrated; Height (without accessories): 10 in; Diameter (without cable or plug): 9.06 in | Maximum capacity (nominal load): 500 kN; Calibration: Calibrated; Height (without accessories): 6.18 in; Diameter (without cable or plug): 5.12 in | Maximum capacity (nominal load): 50 kN; Calibration: Calibrated; Height (without accessories): 2.83 in; Diameter (without cable or plug): 2.76 in | Maximum capacity (nominal load): 5 MN; Calibration: Calibrated; Height (without accessories): 11.93 in; Diameter (without cable or plug): 10.83 in | 10 kN rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression | 5000 kN rated capacity = 5,000 kN (509.8581 t mass equivalent at standard gravity); compression |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Analog 0-10V | Analog 0-10V |
| Force range | 0–100000 N | 0–10000 N | 0–1000000 N | 0–200000 N | 0–20000 N | 0–2000000 N | 0–300000 N | 0–3000000 N | 0–500000 N | 0–50000 N | 0–5000000 N | 0–10000 N | 0–5000000 N |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | True | True | True | True | Not specified | Not specified |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| Accuracy class | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% |
| Numeric manufacturer accuracy class | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.02 % | 0.02 % |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Ethernet | Ethernet |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 40000 samples/s | 40000 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-C18/100KN (opens in a new tab) | PDF — 1-C18/10KN (opens in a new tab) | PDF — 1-C18/1MN (opens in a new tab) | PDF — 1-C18/200KN (opens in a new tab) | PDF — 1-C18/20KN (opens in a new tab) | PDF — 1-C18/2MN (opens in a new tab) | PDF — 1-C18/300KN (opens in a new tab) | PDF — 1-C18/3MN (opens in a new tab) | PDF — 1-C18/500KN (opens in a new tab) | PDF — 1-C18/50KN (opens in a new tab) | PDF — 1-C18/5MN (opens in a new tab) | PDF — C18-10kN (opens in a new tab) | PDF — C18-5000kN (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. C18 is a compressive reference force transducer based on the ring-torsion principle.
The manufacturer supplies the mounting base and thrust piece. Install the transducer with these parts; omitting them causes measurement errors.
The manufacturer lists nominal capacities from 10 kN to 5 MN. Select the capacity for the measurement task.
The manufacturer also positions C18 for mobile applications, citing its compact design and low weight relative to capacity.
The manufacturer specifies IP68 and stainless-steel construction for C18.
Get a quote or advice
Tell us what you need and an engineer will come back to you.