Skip to content

C18 Force

Reference compression force transducer for calibration up to 5 MN. Rated IP68 for use with reference measurement rigs and in calibration laboratories.

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C18
Force range 0–5000000 N

Models in the series

One column per model: what differs between the models of the series.

Models of C18 compared by parameter
Parameter 1-C18/100KN 1-C18/10KN 1-C18/1MN 1-C18/200KN 1-C18/20KN 1-C18/2MN 1-C18/300KN 1-C18/3MN 1-C18/500KN 1-C18/50KN 1-C18/5MN C18-10kN C18-5000kN
Load mode Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only
Protection class (DIN EN 60529) IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified
Technical specification details Maximum capacity (nominal load): 100 kN; Calibration: Calibrated; Height (without accessories): 3.5 in; Diameter (without cable or plug): 2.95 in Maximum capacity (nominal load): 10 kN; Calibration: Fulfills ISO 376; Height (without accessories): 2.83 in; Diameter (without cable or plug): 2.76 in Maximum capacity (nominal load): 1 MN; Calibration: Calibrated; Height (without accessories): 6.73 in; Diameter (without cable or plug): 5.91 in Maximum capacity (nominal load): 200 kN; Calibration: Calibrated; Height (without accessories): 3.5 in; Diameter (without cable or plug): 2.95 in Maximum capacity (nominal load): 20 kN; Calibration: Calibrated; Height (without accessories): 2.83 in; Diameter (without cable or plug): 2.76 in Maximum capacity (nominal load): 2 MN; Calibration: Calibrated; Height (without accessories): 9.41 in; Diameter (without cable or plug): 9.06 in Maximum capacity (nominal load): 300 kN; Calibration: Calibrated; Height (without accessories): 4.41 in; Diameter (without cable or plug): 3.74 in Maximum capacity (nominal load): 3 MN; Calibration: Calibrated; Height (without accessories): 10 in; Diameter (without cable or plug): 9.06 in Maximum capacity (nominal load): 500 kN; Calibration: Calibrated; Height (without accessories): 6.18 in; Diameter (without cable or plug): 5.12 in Maximum capacity (nominal load): 50 kN; Calibration: Calibrated; Height (without accessories): 2.83 in; Diameter (without cable or plug): 2.76 in Maximum capacity (nominal load): 5 MN; Calibration: Calibrated; Height (without accessories): 11.93 in; Diameter (without cable or plug): 10.83 in 10 kN rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression 5000 kN rated capacity = 5,000 kN (509.8581 t mass equivalent at standard gravity); compression
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Analog 0-10V Analog 0-10V
Force range 0–100000 N 0–10000 N 0–1000000 N 0–200000 N 0–20000 N 0–2000000 N 0–300000 N 0–3000000 N 0–500000 N 0–50000 N 0–5000000 N 0–10000 N 0–5000000 N
Sampling rate limited by system readout True True True True True True True True True True True Not specified Not specified
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
Accuracy class ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩
Numeric manufacturer accuracy class 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0.02 % 0.02 %
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Ethernet Ethernet
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 40000 samples/s 40000 samples/s
Status Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-C18/100KN (opens in a new tab) PDF — 1-C18/10KN (opens in a new tab) PDF — 1-C18/1MN (opens in a new tab) PDF — 1-C18/200KN (opens in a new tab) PDF — 1-C18/20KN (opens in a new tab) PDF — 1-C18/2MN (opens in a new tab) PDF — 1-C18/300KN (opens in a new tab) PDF — 1-C18/3MN (opens in a new tab) PDF — 1-C18/500KN (opens in a new tab) PDF — 1-C18/50KN (opens in a new tab) PDF — 1-C18/5MN (opens in a new tab) PDF — C18-10kN (opens in a new tab) PDF — C18-5000kN (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. C18 is a compressive reference force transducer based on the ring-torsion principle.

The manufacturer supplies the mounting base and thrust piece. Install the transducer with these parts; omitting them causes measurement errors.

The manufacturer lists nominal capacities from 10 kN to 5 MN. Select the capacity for the measurement task.

The manufacturer also positions C18 for mobile applications, citing its compact design and low weight relative to capacity.

The manufacturer specifies IP68 and stainless-steel construction for C18.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words