Skip to content

C2/C2A Force

Analog compression load-cell family for weighing, with a spherical load introduction surface and IP67 protection.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for C2/C2A
Ordering options and constraints K-C2A — capacity: 2204.62 lb, 4409.24 lb, 11023.11 lb, 22046.22 lb; accuracy_class: D1, C3, C4; constraints: []
Ordering options and constraints K-C2_ — capacity: 110.23 lb, 220.46 lb, 440.92 lb, 1102.31 lb, 2204.62 lb, 4409.24 lb, 11023.11 lb, 22046.22 lb, 44092.45 lb, 110231.131 lb; accuracy_class: 0.2, 0.1; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C2/C2A
Protection class (DIN EN 60529) IP67
Operating temperature -30–70 °C
Force range 0–4903.319169 N
Accuracy (% FSO) 0.1–0.2 %
Numeric manufacturer accuracy class 0.1–0.2
Nominal force capacity 490.3274687–490332.4996 N

Models in the series

One column per model: what differs between the models of the series.

Models of C2/C2A compared by parameter
Parameter 1-C2/100KG 1-C2/10T 1-C2/1T 1-C2/200KG 1-C2/20T 1-C2/2T 1-C2/500KG 1-C2/50KG 1-C2/50T 1-C2/5T K-C2_ · 110.23 lb K-C2_ · 1102.31 lb K-C2_ · 11023.11 lb K-C2_ · 110231.131 lb K-C2_ · 220.46 lb K-C2_ · 2204.62 lb K-C2_ · 22046.22 lb K-C2_ · 440.92 lb K-C2_ · 4409.24 lb K-C2_ · 44092.45 lb K-C2A · 11023.11 lb K-C2A · 2204.62 lb K-C2A · 22046.22 lb K-C2A · 4409.24 lb
Load mode Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only Compression only
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Operating temperature -30–85 °C -30–85 °C -30–85 °C -30–85 °C -30–85 °C -30–85 °C -30–85 °C -30–85 °C -30–85 °C -30–85 °C Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Force range 0–980.665 N 0–98066.5 N 0–9806.65 N 0–1961.33 N 0–196133 N 0–19613.3 N 0–4903.325 N 0–490.3325 N 0–490332.5 N 0–49033.25 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Accuracy (% FSO) 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.2 % 0.1 % 0.1 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate limited by system readout True True True True True True True True True True Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Maximum capacity: 220.4 lb; Accuracy class: 0.1 Maximum capacity: 22040 lb; Accuracy class: 0.1 Maximum capacity: 2204 lb; Accuracy class: 0.1 Maximum capacity: 440 lb, 8 lb; Accuracy class: 0.1 Maximum capacity: 44080 lb; Accuracy class: 0.1 Maximum capacity: 4408 lb; Accuracy class: 0.1 Maximum capacity: 1102 lb; Accuracy class: 0.1 Maximum capacity: 110 lb, 2 lb; Accuracy class: 0.2 Maximum capacity: 110200 lb; Accuracy class: 0.1 Maximum capacity: 11020 lb; Accuracy class: 0.1 Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Linearity reference Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.2; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: 0.1; retained as a class, not converted to overall installed-chain accuracy. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Accuracy class ⁦0.1%⁩ ⁦0.1%⁩ ⁦0.1%⁩ ⁦0.1%⁩ ⁦0.1%⁩ ⁦0.1%⁩ ⁦0.1%⁩ ⁦0.2%⁩ ⁦0.1%⁩ ⁦0.1%⁩ Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Numeric manufacturer accuracy class 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.1 Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 110.23 lb nominal force capacity 1102.31 lb nominal force capacity 11023.11 lb nominal force capacity 110231.131 lb nominal force capacity 220.46 lb nominal force capacity 2204.62 lb nominal force capacity 22046.22 lb nominal force capacity 440.92 lb nominal force capacity 4409.24 lb nominal force capacity 44092.45 lb nominal force capacity 11023.11 lb nominal force capacity 2204.62 lb nominal force capacity 22046.22 lb nominal force capacity 4409.24 lb nominal force capacity
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 490.3274687 N 4903.319169 N 49033.23617 N 490332.4996 N 980.6549373 N 9806.638338 N 98066.47234 N 1961.309875 N 19613.27668 N 196132.9892 N 49033.23617 N 9806.638338 N 98066.47234 N 19613.27668 N
Published accuracy class Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: 0.2, 0.1 Official family-table accuracy class: D1, C3, C4 Official family-table accuracy class: D1, C3, C4 Official family-table accuracy class: D1, C3, C4 Official family-table accuracy class: D1, C3, C4
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-C2/100KG (opens in a new tab) PDF — 1-C2/10T (opens in a new tab) PDF — 1-C2/1T (opens in a new tab) PDF — 1-C2/200KG (opens in a new tab) PDF — 1-C2/20T (opens in a new tab) PDF — 1-C2/2T (opens in a new tab) PDF — 1-C2/500KG (opens in a new tab) PDF — 1-C2/50KG (opens in a new tab) PDF — 1-C2/50T (opens in a new tab) PDF — 1-C2/5T (opens in a new tab) PDF — K-C2_ · 110.23 lb (opens in a new tab) PDF — K-C2_ · 1102.31 lb (opens in a new tab) PDF — K-C2_ · 11023.11 lb (opens in a new tab) PDF — K-C2_ · 110231.131 lb (opens in a new tab) PDF — K-C2_ · 220.46 lb (opens in a new tab) PDF — K-C2_ · 2204.62 lb (opens in a new tab) PDF — K-C2_ · 22046.22 lb (opens in a new tab) PDF — K-C2_ · 440.92 lb (opens in a new tab) PDF — K-C2_ · 4409.24 lb (opens in a new tab) PDF — K-C2_ · 44092.45 lb (opens in a new tab) PDF — K-C2A · 11023.11 lb (opens in a new tab) PDF — K-C2A · 2204.62 lb (opens in a new tab) PDF — K-C2A · 22046.22 lb (opens in a new tab) PDF — K-C2A · 4409.24 lb (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Both families are designed for compression loads. Apply the load through the designated load introduction point and check alignment in the fixture.

The C2 is offered in rated capacities from 50 kg to 50 t. The C2A is offered in 1, 2, 5 and 10 t capacities according to its ordering specification.

The C2A is available in OIML R60 classes D1, C3 and C4. The classification applies to the ordered version. Check the approval requirements for the full weighing system as well.

These load cells use a strain-gauge bridge with an mV/V signal and a six-wire connection. Use a weighing amplifier or transmitter that supplies excitation and reads the bridge output.

Check the operating load per cell, including dead weight and the distribution across supports. The manufacturer’s data also specifies limits for lateral force and overload.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words