Skip to content

FS62CSS Strain

FS62CSS measures strain in one direction on substrates such as concrete, steel and composites. The sensing area helps average local variations on nonuniform surfaces. The sensor bonds to the structure and can be ordered with a metal-free aramid cable or an armored cable.

Visit the HBK site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of FS62CSS compared by parameter
Parameter 1-FS62CSS-ARM/1510 1-FS62CSS-ARM/1520 1-FS62CSS-ARM/1530 1-FS62CSS-ARM/1540 1-FS62CSS-ARM/1550 1-FS62CSS-ARM/1560 1-FS62CSS-ARM/1570 1-FS62CSS-ARM/1580 1-FS62CSS-ARM/1590 K-FS62CSS
Technical specification details Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; Linear; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Status Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It can be bonded to concrete, steel and composites. Surface preparation and adhesive selection depend on the substrate and installation conditions.

The specified strain range is ±5,000 µm/m along the sensing direction.

Choose aramid where the cable must be free of metallic components. An armored cable adds mechanical protection where the fiber route is exposed to damage.

Check the curvature of the mounting surface. The datasheet specifies a bend radius greater than 1,000 mm for the sensor itself.

HBK recommends the FS63CTS optical temperature sensor as a companion measurement. Apply compensation in data processing for the structure and measurement conditions.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words