FS62PSR Strain

FS62PSR combines three FBGs on one flexible patch to measure strain at different angles at the same location. These readings support in-plane strain analysis. The rosette bonds to flat or curved surfaces within the mounting limits.

Visit the HBK site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of FS62PSR compared by parameter
Parameter 1-FS62PSR-3505 1-FS62PSR-3520 1-FS62PSR-3535 1-FS62PSR-3550 1-FS62PSR-3565 1-FS62PSR-3580 K-FS62PSR
Technical specification details Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Bondable
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The three directions relative to the rosette reference axis are 0°, 60° and 120°.

Use the rosette when in-plane strain analysis is needed, for example when the principal strain direction is unknown beforehand.

The specified range is ±10,000 µm/m per grating. For high-strain tests, select wavelengths that keep the signals distinct across the measurement.

Bond the rosette after preparing the surface. Align its reference mark before bonding so the three readings can be interpreted correctly.

An FS63LTS can be installed close to the sensing location to provide a temperature reading for compensation during data processing.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words