FS62WSR Strain

FS62WSR measures strain in three directions at one location on a metal structure using a spot-welded rosette. Braided, aramid and armored versions cover different installation environments. Check the temperature range and bend limit for the chosen version.

Visit the HBK site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of FS62WSR compared by parameter
Parameter 1-FS62WSR-ARM/3505 1-FS62WSR-ARM/3520 1-FS62WSR-ARM/3535 1-FS62WSR-ARM/3550 1-FS62WSR-ARM/3565 1-FS62WSR-ARM/3580 K-FS62WSR
Technical specification details Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The rosette reads in three directions, 0°, 60° and 120°, for in-plane strain analysis.

The nominal range is ±2,000 µm/m per grating. For high strain, check the wavelength spacing so the signals do not overlap.

Align the rosette to the required reference direction and spot-weld its substrate in accordance with the variant’s mounting instructions. There is no adhesive cure time between the substrate and the structure.

The braided cable serves, among other uses, higher-temperature laboratory tests. Aramid and armored versions are available for outdoor installations. The connector may have a different temperature range from the cable or sensor.

Select a temperature sensor suited to the installation, such as the spot-weldable FS63WTS. Use its temperature reading when processing the strain data.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words