FS62WSR Strain
FS62WSR measures strain in three directions at one location on a metal structure using a spot-welded rosette. Braided, aramid and armored versions cover different installation environments. Check the temperature range and bend limit for the chosen version.
Visit the HBK site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-FS62WSR-ARM/3505 | 1-FS62WSR-ARM/3520 | 1-FS62WSR-ARM/3535 | 1-FS62WSR-ARM/3550 | 1-FS62WSR-ARM/3565 | 1-FS62WSR-ARM/3580 | K-FS62WSR |
|---|---|---|---|---|---|---|---|
| Technical specification details | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable | Strain gauge; 3-grid rosette; FBG (ca. 0.79); Limited temperature range; No matching of temperature response; Optical fiber (for optical fibers (FC/APC, SC/APC, splice); Weldable |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| Status | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The rosette reads in three directions, 0°, 60° and 120°, for in-plane strain analysis.
The nominal range is ±2,000 µm/m per grating. For high strain, check the wavelength spacing so the signals do not overlap.
Align the rosette to the required reference direction and spot-weld its substrate in accordance with the variant’s mounting instructions. There is no adhesive cure time between the substrate and the structure.
The braided cable serves, among other uses, higher-temperature laboratory tests. Aramid and armored versions are available for outdoor installations. The connector may have a different temperature range from the cable or sensor.
Select a temperature sensor suited to the installation, such as the spot-weldable FS63WTS. Use its temperature reading when processing the strain data.
Get a quote or advice
Tell us what you need and an engineer will come back to you.