Skip to content

Models in the series

One column per model: what differs between the models of the series.

Models of P60 compared by parameter
Parameter 1-P60A/100BAR-3 1-P60A/200BAR-3 1-P60A/20BAR-3 1-P60A/50BAR-3 1-P60B/100BAR-3 1-P60B/200BAR-3 1-P60B/20BAR-3 1-P60B/50BAR-3 1-P60C/100BAR-3 1-P60C/200BAR-3 1-P60C/20BAR-3 1-P60C/50BAR-3 1-P60D/100BAR-3 1-P60D/200BAR-3 1-P60D/20BAR-3 1-P60D/50BAR-3 1-P60E/100BAR-3 1-P60E/200BAR-3 1-P60E/20BAR-3 1-P60E/50BAR-3 1-P60F/100BAR-3 1-P60F/200BAR-3 1-P60F/20BAR-3 1-P60F/50BAR-3
Technical specification details 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 200 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 20 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 50 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 200 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 20 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 50 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 200 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 20 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 50 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 200 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 20 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 50 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 200 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 20 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 50 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 200 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 20 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug 0 to 50 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug
Pressure range 0–100 bar 0–200 bar 0–20 bar 0–50 bar 0–100 bar 0–200 bar 0–20 bar 0–50 bar 0–100 bar 0–200 bar 0–20 bar 0–50 bar 0–100 bar 0–200 bar 0–20 bar 0–50 bar 0–100 bar 0–200 bar 0–20 bar 0–50 bar 0–100 bar 0–200 bar 0–20 bar 0–50 bar
Pressure reference Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure Gauge / relative pressure
Protection class (DIN EN 60529) IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45 IP45
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Operating temperature -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C -40–160 °C
Pressure range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Nominal ranges are 20, 50, 100 and 200 bar. Select the range using the maximum expected pressure at the measurement point, including transient peaks.

The compact housing suits liquid-pressure measurements at space-constrained points, such as gearbox oil, hydraulic circuits and vehicle cooling circuits.

HBK specifies operation up to 150°C. Check the sensor, measuring cable and connector conditions against the limits of the selected version.

HBK specifies accuracy class 0.3. A system uncertainty estimate also needs to account for temperature and the signal-acquisition equipment.

The family offers six threaded connection options. Match the thread and sealing interface to the pressure port and allow access to the electrical connector.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words