PACEline CFTplus Force
Piezoelectric compression force transducer for dynamic measurements with rated capacities up to 120 kN. Passive charge signal for a charge amplifier and IP65 protection.
Download the datasheet (opens in a new tab) Visit the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -40–120 °C |
|---|---|
| Force range | 0–70000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | PACEline CFTplus-120kN | PACEline CFTplus-25kN | PACEline CFTplus-50kN | PACEline CFTplus-70kN |
|---|---|---|---|---|
| Load mode | Compression only | Compression only | Compression only | Compression only |
| Protection class (DIN EN 60529) | IP65 | IP65 | IP65 | IP65 |
| Operating temperature | -40–120 °C | -40–120 °C | -40–120 °C | -40–120 °C |
| Force range | 0–120000 N | 0–25000 N | 0–50000 N | 0–70000 N |
| Interfaces | PROFINET | PROFINET | Ethernet | Ethernet |
| Outputs and interfaces | Analog 0-10V | Digital I/O | Analog 0-10V | Analog 0-10V |
| Technical specification details | 120 kN rated capacity = 120 kN (12.2366 t mass equivalent at standard gravity); compression | 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression | 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression | 70 kN rated capacity = 70 kN (7.138 t mass equivalent at standard gravity); compression |
| Accuracy (% FSO) | 0.5 % | 0.5 % | 0.5 % | 0.5 % |
| Sampling rate reference | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — PACEline CFTplus-120kN (opens in a new tab) | PDF — PACEline CFTplus-25kN (opens in a new tab) | PDF — PACEline CFTplus-50kN (opens in a new tab) | PDF — PACEline CFTplus-70kN (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is a piezoelectric compression-force transducer with 25, 50, 70 and 120 kN nominal-force versions. Select a version for the application rather than treating them as one head’s adjustable range.
No. Sensitivities in pC/N differ. The 25 kN version uses gallium phosphate and the others quartz. Use the particular head’s sensitivity.
It is a mechanical load limit, not a tensile measurement calibration. The manufacturer’s footnote states that the sensor is not calibrated in tension.
The table specifies IP65 and IP67 with cable 1-KAB145. Preserve that cable condition rather than assigning IP67 to every combination.
No. The datasheet distinguishes repeatability/reproducibility at unchanged mounting, linearity deviation and hysteresis. Use each property for its intended assessment and reference basis.