PACEline CFW Force
Piezoelectric compression washer with standard bore sizes. Rated IP65, connected to a charge amplifier and calibrated after integration into the assembly.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–700000 N |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-CFW/100KN | 1-CFW/140KN | 1-CFW/190KN | 1-CFW/20KN | 1-CFW/330KN | 1-CFW/50KN | 1-CFW/700KN |
|---|---|---|---|---|---|---|---|
| Load mode | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only |
| Protection class (DIN EN 60529) | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
| Force range | 0–100000 N | 0–140000 N | 0–190000 N | 0–20000 N | 0–330000 N | 0–50000 N | 0–700000 N |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. |
| Linearity reference | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. |
| Technical specification details | Maximum capacity (nominal load): 100 kN; Height (without accessories): 0.433 in; Diameter (without cable or plug): 1.122 in | Maximum capacity (nominal load): 140 kN; Height (without accessories): 0.472 in; Diameter (without cable or plug): 1.358265 in | Maximum capacity (nominal load): 190 kN; Height (without accessories): 0.512 in; Diameter (without cable or plug): 1.594485 in | Maximum capacity (nominal load): 20 kN; Height (without accessories): 0.315 in; Diameter (without cable or plug): 0.570865 in | Maximum capacity (nominal load): 330 kN; Height (without accessories): 0.591 in; Diameter (without cable or plug): 2.066925 in | Maximum capacity (nominal load): 50 kN; Height (without accessories): 0.394 in; Diameter (without cable or plug): 0.886 in | Maximum capacity (nominal load): 700 kN; Height (without accessories): 0.669 in; Diameter (without cable or plug): 2.972435 in |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| Sampling rate limited by system readout | True | True | True | True | True | True | True |
| Status | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-CFW/100KN (opens in a new tab) | PDF — 1-CFW/140KN (opens in a new tab) | PDF — 1-CFW/190KN (opens in a new tab) | PDF — 1-CFW/20KN (opens in a new tab) | PDF — 1-CFW/330KN (opens in a new tab) | PDF — 1-CFW/50KN (opens in a new tab) | PDF — 1-CFW/700KN (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
CFW is a piezoelectric force washer with charge sensitivity in pC/N. Use a compatible charge amplifier rather than a direct mV/V bridge input.
No. The manufacturer requires calibration under mounting conditions. The preload bolt and force distribution in the assembly affect the measured signal.
The table qualifies IP65 by a connected charge cable. Do not apply it to an unmated socket or another undocumented connection assembly.
No. Resonance frequencies vary by capacity. Acquisition rate and system response also depend on the amplifier and the mechanical structure containing the washer.
Use the nominal-capacity drawing and corresponding centering sleeve. Force capacity alone is insufficient if diameter, preload bolt and load conditions do not fit.