PACEline CLP Force
Low-profile piezoelectric compression washer for tight installations. Integrated cable, IP65 protection and passive charge output for an external amplifier.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–80000 N |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-CLP/14KN | 1-CLP/14KN-0.5M | 1-CLP/26KN | 1-CLP/26KN-0.5M | 1-CLP/36KN | 1-CLP/36KN-0.5M | 1-CLP/3KN | 1-CLP/3KN-0.5M | 1-CLP/62KN | 1-CLP/62KN-0.5M | 1-CLP/7KN | 1-CLP/7KN-0.5M | 1-CLP/80KN | 1-CLP/80KN-0.5M | PACEline CLP-14kN | PACEline CLP-26kN | PACEline CLP-36kN | PACEline CLP-3kN | PACEline CLP-62kN | PACEline CLP-7kN | PACEline CLP-80kN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only |
| Protection class (DIN EN 60529) | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
| Force range | 0–14000 N | 0–14000 N | 0–26000 N | 0–26000 N | 0–36000 N | 0–36000 N | 0–3000 N | 0–3000 N | 0–62000 N | 0–62000 N | 0–7000 N | 0–7000 N | 0–80000 N | 0–80000 N | 0–14000 N | 0–26000 N | 0–36000 N | 0–3000 N | 0–62000 N | 0–7000 N | 0–80000 N |
| Technical specification details | Maximum capacity (nominal load): 14 kN; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.307086 in | Maximum capacity (nominal load): 14 kN; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.307086 in | Maximum capacity (nominal load): 26 kN; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.385826 in | Maximum capacity (nominal load): 26 kN; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.385826 in | Maximum capacity (nominal load): 36 kN; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.464566 in | Maximum capacity (nominal load): 36 kN; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.464566 in | Maximum capacity (nominal load): 3 kN; Height (without accessories): 0.118 in; Diameter (without cable or plug): 0.1594485 in | Maximum capacity (nominal load): 3 kN; Height (without accessories): 0.118 in; Diameter (without cable or plug): 0.1594485 in | Maximum capacity (nominal load): 62 kN; Height (without accessories): 0.157 in; Diameter (without cable or plug): 0.543306 in | Maximum capacity (nominal load): 62 kN; Height (without accessories): 0.157 in; Diameter (without cable or plug): 0.543306 in | Maximum capacity (nominal load): 7 kN; Height (without accessories): 0.118 in; Diameter (without cable or plug): 0.216535 in | Maximum capacity (nominal load): 7 kN; Height (without accessories): 0.118 in; Diameter (without cable or plug): 0.216535 in | Maximum capacity (nominal load): 80 kN; Height (without accessories): 0.197 in; Diameter (without cable or plug): 0.622046 in | Maximum capacity (nominal load): 80 kN; Height (without accessories): 0.197 in; Diameter (without cable or plug): 0.622046 in | 14 kN rated capacity = 14 kN (1.4276 t mass equivalent at standard gravity); compression | 26 kN rated capacity = 26 kN (2.6513 t mass equivalent at standard gravity); compression | 36 kN rated capacity = 36 kN (3.671 t mass equivalent at standard gravity); compression | 3 kN rated capacity = 3 kN (305.9149 kg mass equivalent at standard gravity); compression | 62 kN rated capacity = 62 kN (6.3222 t mass equivalent at standard gravity); compression | 7 kN rated capacity = 7 kN (713.8013 kg mass equivalent at standard gravity); compression | 80 kN rated capacity = 80 kN (8.1577 t mass equivalent at standard gravity); compression |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted | Charge-amplifier filter and output configuration determine the usable bandwidth; no unsupported digital rate is asserted |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Linearity reference | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | HBK accuracy class: 1; retained as a class, not converted to overall installed-chain accuracy. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Analog 0-10V | Analog 0-10V | Analog 0-10V | Digital I/O | Analog 0-10V | Analog 0-10V | Digital I/O |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Ethernet | Ethernet | PROFINET | Ethernet | EtherCAT | PROFINET | PROFINET |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 % | 1 % | 1 % | 1 % | 1 % | 1 % | 1 % |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-CLP/14KN (opens in a new tab) | PDF — 1-CLP/14KN-0.5M (opens in a new tab) | PDF — 1-CLP/26KN (opens in a new tab) | PDF — 1-CLP/26KN-0.5M (opens in a new tab) | PDF — 1-CLP/36KN (opens in a new tab) | PDF — 1-CLP/36KN-0.5M (opens in a new tab) | PDF — 1-CLP/3KN (opens in a new tab) | PDF — 1-CLP/3KN-0.5M (opens in a new tab) | PDF — 1-CLP/62KN (opens in a new tab) | PDF — 1-CLP/62KN-0.5M (opens in a new tab) | PDF — 1-CLP/7KN (opens in a new tab) | PDF — 1-CLP/7KN-0.5M (opens in a new tab) | PDF — 1-CLP/80KN (opens in a new tab) | PDF — 1-CLP/80KN-0.5M (opens in a new tab) | PDF — PACEline CLP-14kN (opens in a new tab) | PDF — PACEline CLP-26kN (opens in a new tab) | PDF — PACEline CLP-36kN (opens in a new tab) | PDF — PACEline CLP-3kN (opens in a new tab) | PDF — PACEline CLP-62kN (opens in a new tab) | PDF — PACEline CLP-7kN (opens in a new tab) | PDF — PACEline CLP-80kN (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
CLP is a flat piezoelectric force washer for integration into a mechanical structure. It produces charge and requires a suitable acquisition chain.
No. The 3–80 kN versions have separate table entries and dimensions. Washer height and diameters depend on nominal force.
The manufacturer requires calibration under mounting conditions. Typical table sensitivity does not replace the force-distribution effects of the assembled structure.
The table footnote requires an initial preload of at least 20% of nominal force. Preserve that condition with the linearity value.
The table specifies IP65 and an integral charge cable with a 10-32 UNF connector. Also match the amplifier-side connection and installation conditions.