PW37P Force
PW37P: sensors and measurement devices by HBK for force.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–1961.33 N |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-PW37PC3/100KG-1 | 1-PW37PC3/200KG-1 | 1-PW37PC3/50KG-1 | 1-PW37PY/100KG-1 | 1-PW37PY/200KG-1 | 1-PW37PY/50KG-1 |
|---|---|---|---|---|---|---|
| Sampling rate limited by system readout | True | True | True | True | True | True |
| Force range | 0–980.665 N | 0–1961.33 N | 0–490.3325 N | 0–980.665 N | 0–1961.33 N | 0–490.3325 N |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. |
| Technical specification details | Maximum capacity: 220.46 lb; Minimum verification interval (Vmin): 10 g | Maximum capacity: 441 lb; Minimum verification interval (Vmin): 20 g | Maximum capacity: 110.2 lb; Minimum verification interval (Vmin): 5 g | Maximum capacity: 220.46 lb; Minimum verification interval (Vmin): 5 g | Maximum capacity: 441 lb; Minimum verification interval (Vmin): 10 g | Maximum capacity: 110.2 lb; Minimum verification interval (Vmin): 2 g |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. |
| Accuracy class | C3 Multi Range (MR) | C3 Multi Range (MR) | C3 Multi Range (MR) | C3 Multi Range (MR) | C3 Multi Range (MR) | C3 Multi Range (MR) |
| Status | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-PW37PC3/100KG-1 (opens in a new tab) | PDF — 1-PW37PC3/200KG-1 (opens in a new tab) | PDF — 1-PW37PC3/50KG-1 (opens in a new tab) | PDF — 1-PW37PY/100KG-1 (opens in a new tab) | PDF — 1-PW37PY/200KG-1 (opens in a new tab) | PDF — 1-PW37PY/50KG-1 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The series offers nominal capacities of 50, 100 and 200 kg. Select the ordering code for the required capacity.
The load cell uses stainless steel, an EHEDG-certified design and a hygienic M12 cable connection.
HBK specifies C3 Multi Range under OIML R60. This load-cell class alone does not determine complete-system weighing accuracy.
HBK specifies IP68 tested under a 1 m water column for 100 hours, plus IP69K under the datasheet test conditions.
The datasheet specifies platforms up to 600 × 600 mm. Follow the load-application and mounting instructions.
The analog output is rated in mV/V, with nominal sensitivity of 2 mV/V. It is not a direct 0–10 V or 4–20 mA output.
Get a quote or advice
Tell us what you need and an engineer will come back to you.