Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of PW37P
Force range 0–1961.33 N

Models in the series

One column per model: what differs between the models of the series.

Models of PW37P compared by parameter
Parameter 1-PW37PC3/100KG-1 1-PW37PC3/200KG-1 1-PW37PC3/50KG-1 1-PW37PY/100KG-1 1-PW37PY/200KG-1 1-PW37PY/50KG-1
Sampling rate limited by system readout True True True True True True
Force range 0–980.665 N 0–1961.33 N 0–490.3325 N 0–980.665 N 0–1961.33 N 0–490.3325 N
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred.
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate.
Technical specification details Maximum capacity: 220.46 lb; Minimum verification interval (Vmin): 10 g Maximum capacity: 441 lb; Minimum verification interval (Vmin): 20 g Maximum capacity: 110.2 lb; Minimum verification interval (Vmin): 5 g Maximum capacity: 220.46 lb; Minimum verification interval (Vmin): 5 g Maximum capacity: 441 lb; Minimum verification interval (Vmin): 10 g Maximum capacity: 110.2 lb; Minimum verification interval (Vmin): 2 g
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code.
Accuracy class C3 Multi Range (MR) C3 Multi Range (MR) C3 Multi Range (MR) C3 Multi Range (MR) C3 Multi Range (MR) C3 Multi Range (MR)
Status Active Active Active Active Active Active
Datasheet PDF — 1-PW37PC3/100KG-1 (opens in a new tab) PDF — 1-PW37PC3/200KG-1 (opens in a new tab) PDF — 1-PW37PC3/50KG-1 (opens in a new tab) PDF — 1-PW37PY/100KG-1 (opens in a new tab) PDF — 1-PW37PY/200KG-1 (opens in a new tab) PDF — 1-PW37PY/50KG-1 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The series offers nominal capacities of 50, 100 and 200 kg. Select the ordering code for the required capacity.

The load cell uses stainless steel, an EHEDG-certified design and a hygienic M12 cable connection.

HBK specifies C3 Multi Range under OIML R60. This load-cell class alone does not determine complete-system weighing accuracy.

HBK specifies IP68 tested under a 1 m water column for 100 hours, plus IP69K under the datasheet test conditions.

The datasheet specifies platforms up to 600 × 600 mm. Follow the load-application and mounting instructions.

The analog output is rated in mV/V, with nominal sensitivity of 2 mV/V. It is not a direct 0–10 V or 4–20 mA output.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough