Skip to content

PW4M-OP Force

HBK’s PW4M‑OP is intended for compact weighing platforms in filling and checkweighing machines. The family spans 0.3 to 5 kg, with OIML R60 class C3 versions. The built-in stop protects the load cell against overload. Check the rated capacity, platform size and ingress protection for the exact order code.

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for PW4M-OP
Ordering options and constraints K-PW4M-OP — capacity: 0.661 lb, 4.409 lb, 11.023 lb; degree_of_protection: IP67; minimum_verification_interval_vmin: 0.05 g, 0.2 g, 1 g; special_feature: None; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of PW4M-OP
Force range 0–2.940274488 N
Operating temperature -10–50 °C
Protection class (DIN EN 60529) IP67
Nominal force capacity 2.940274488–49.03274687 N
ADC sampling rate 19200–40000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of PW4M-OP compared by parameter
Parameter 1-PW4MC3/1KGOP-1 1-PW4MC3/2KGOP-1 1-PW4MC3/300GOP-1 1-PW4MC3/3KGOP-1 1-PW4MC3/500GOP-1 1-PW4MC3/5KGOP-1 K-PW4M-OP · 0.661 lb K-PW4M-OP · 11.023 lb K-PW4M-OP · 4.409 lb PW4M-OP-0p3kg PW4M-OP-5kg
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0–2.941995 N 0–49.03325 N
Operating temperature -10–50 °C -10–50 °C -10–50 °C -10–50 °C -10–50 °C -10–50 °C Not specified Not specified Not specified -10–50 °C -10–50 °C
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 Not specified Not specified Not specified IP67 IP67
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. Not specified Not specified Not specified LCMC digital update rate is variant- and filter-dependent; confirm it for the ordered chain LCMC measurement-chain update rate is variant- and filter-dependent; confirm it for the ordered chain
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified RS422 / RS485 Analog 0-10V
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified Not specified
Technical specification details Maximum capacity: 2.2 lb; Degree of protection: IP65; Minimum verification interval (Vmin): 0.2 g; Special feature: Integrated overload protection Maximum capacity: 4.41 lb; Degree of protection: IP65; Minimum verification interval (Vmin): 0.2 g; Special feature: Integrated overload protection Maximum capacity: 0.66 lb; Degree of protection: IP65; Minimum verification interval (Vmin): 50 g; Special feature: Integrated overload protection Maximum capacity: 6.61 lb; Degree of protection: IP65; Minimum verification interval (Vmin): 0.5 g; Special feature: Integrated overload protection Maximum capacity: 1.1 lb; Degree of protection: IP65; Minimum verification interval (Vmin): 0.1 g; Special feature: Integrated overload protection Maximum capacity: 11.02 lb; Degree of protection: IP65; Minimum verification interval (Vmin): 1 g; Special feature: Integrated overload protection Not specified Not specified Not specified 0.3 kg rated capacity = 2.942 N (0.3 kg mass equivalent at standard gravity); compression 5 kg rated capacity = 49.0332 N (5 kg mass equivalent at standard gravity); compression
Sampling rate limited by system readout True True True True True True Not specified Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified
Accuracy class C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified 0.661 lb nominal force capacity 11.023 lb nominal force capacity 4.409 lb nominal force capacity Not specified Not specified
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified 2.940274488 N 49.03274687 N 19.6122091 N Not specified Not specified
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified PROFINET Ethernet
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 19200 samples/s 40000 samples/s
Status Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-PW4MC3/1KGOP-1 (opens in a new tab) PDF — 1-PW4MC3/2KGOP-1 (opens in a new tab) PDF — 1-PW4MC3/300GOP-1 (opens in a new tab) PDF — 1-PW4MC3/3KGOP-1 (opens in a new tab) PDF — 1-PW4MC3/500GOP-1 (opens in a new tab) PDF — 1-PW4MC3/5KGOP-1 (opens in a new tab) PDF — K-PW4M-OP · 0.661 lb (opens in a new tab) PDF — K-PW4M-OP · 11.023 lb (opens in a new tab) PDF — K-PW4M-OP · 4.409 lb (opens in a new tab) PDF — PW4M-OP-0p3kg (opens in a new tab) PDF — PW4M-OP-5kg (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a single-point load cell for small masses, including portion filling and checkweighing. It mounts beneath a compact weighing platform.

The family spans nominal capacities from 0.3 to 5 kg. Allow for the weight of the platform or container when selecting a capacity.

The version includes a built-in overload stop. HBK describes protection up to ten times the nominal capacity under the stated conditions.

HBK lists OIML R60 class C3. Check the verification interval for the order code and the approval requirements for the complete scale.

The manufacturer’s model table lists different ratings by ordering code. Verify the IP rating for the exact variant and consider how it will be mounted in the machine.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words