S2M Force

S-beam strain-gauge sensor for static or dynamic compression and tension. Passive mV/V output and IP67 protection.

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for S2M
Ordering options and constraints K-S2M-MONT — capacity: 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of S2M
Force range 0–1000 N
Nominal force capacity 10–1000 N

Models in the series

One column per model: what differs between the models of the series.

Models of S2M compared by parameter
Parameter 1-S2M/1000N-1 1-S2M/100N-1 1-S2M/10N-1 1-S2M/200N-1 1-S2M/20N-1 1-S2M/500N-1 1-S2M/50N-1 K-S2M-MONT · 1 kN K-S2M-MONT · 10 N K-S2M-MONT · 100 N K-S2M-MONT · 20 N K-S2M-MONT · 200 N K-S2M-MONT · 50 N K-S2M-MONT · 500 N
Load mode Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Force range 0–1000 N 0–100 N 0–10 N 0–200 N 0–20 N 0–500 N 0–50 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate limited by system readout True True True True True True True Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Maximum capacity (nominal load): 1 kN Maximum capacity (nominal load): 100 N Maximum capacity (nominal load): 10 N Maximum capacity (nominal load): 200 N Maximum capacity (nominal load): 20 N Maximum capacity (nominal load): 500 N Maximum capacity (nominal load): 50 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Accuracy class ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩
Numeric manufacturer accuracy class 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1 kN nominal force capacity 10 N nominal force capacity 100 N nominal force capacity 20 N nominal force capacity 200 N nominal force capacity 50 N nominal force capacity 500 N nominal force capacity
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1000 N 10 N 100 N 20 N 200 N 50 N 500 N
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-S2M/1000N-1 (opens in a new tab) PDF — 1-S2M/100N-1 (opens in a new tab) PDF — 1-S2M/10N-1 (opens in a new tab) PDF — 1-S2M/200N-1 (opens in a new tab) PDF — 1-S2M/20N-1 (opens in a new tab) PDF — 1-S2M/500N-1 (opens in a new tab) PDF — 1-S2M/50N-1 (opens in a new tab) PDF — K-S2M-MONT · 1 kN (opens in a new tab) PDF — K-S2M-MONT · 10 N (opens in a new tab) PDF — K-S2M-MONT · 100 N (opens in a new tab) PDF — K-S2M-MONT · 20 N (opens in a new tab) PDF — K-S2M-MONT · 200 N (opens in a new tab) PDF — K-S2M-MONT · 50 N (opens in a new tab) PDF — K-S2M-MONT · 500 N (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

S2M measures tension and compression, with nominal capacities from 10 to 1000 N. These are separate capacity versions, not one sensor’s adjustable range.

The table specifies class 0.02 and separately lists repeatability, linearity, hysteresis and creep. It is not an uncertainty guarantee for every sensor/DAQ combination.

It uses a six-wire connection and 2 mV/V nominal sensitivity. Match a strain-gauge amplifier input, including the sense leads.

No. The datasheet gives −10 to +45°C nominal and −10 to +70°C operating. Operation does not establish identical specified performance throughout that wider interval.

The manufacturer documents a drag-chain-compatible cable and IP67 for the transducer. The drawing gives a 10 mm minimum bend radius; preserve the cable installation requirements.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words