S2M Force
S-beam strain-gauge sensor for static or dynamic compression and tension. Passive mV/V output and IP67 protection.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-S2M-MONT — capacity: 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN; constraints: [] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–1000 N |
|---|---|
| Nominal force capacity | 10–1000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-S2M/1000N-1 | 1-S2M/100N-1 | 1-S2M/10N-1 | 1-S2M/200N-1 | 1-S2M/20N-1 | 1-S2M/500N-1 | 1-S2M/50N-1 | K-S2M-MONT · 1 kN | K-S2M-MONT · 10 N | K-S2M-MONT · 100 N | K-S2M-MONT · 20 N | K-S2M-MONT · 200 N | K-S2M-MONT · 50 N | K-S2M-MONT · 500 N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension |
| Protection class (DIN EN 60529) | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 |
| Force range | 0–1000 N | 0–100 N | 0–10 N | 0–200 N | 0–20 N | 0–500 N | 0–50 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Technical specification details | Maximum capacity (nominal load): 1 kN | Maximum capacity (nominal load): 100 N | Maximum capacity (nominal load): 10 N | Maximum capacity (nominal load): 200 N | Maximum capacity (nominal load): 20 N | Maximum capacity (nominal load): 500 N | Maximum capacity (nominal load): 50 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy class | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% |
| Numeric manufacturer accuracy class | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 kN nominal force capacity | 10 N nominal force capacity | 100 N nominal force capacity | 20 N nominal force capacity | 200 N nominal force capacity | 50 N nominal force capacity | 500 N nominal force capacity |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000 N | 10 N | 100 N | 20 N | 200 N | 50 N | 500 N |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-S2M/1000N-1 (opens in a new tab) | PDF — 1-S2M/100N-1 (opens in a new tab) | PDF — 1-S2M/10N-1 (opens in a new tab) | PDF — 1-S2M/200N-1 (opens in a new tab) | PDF — 1-S2M/20N-1 (opens in a new tab) | PDF — 1-S2M/500N-1 (opens in a new tab) | PDF — 1-S2M/50N-1 (opens in a new tab) | PDF — K-S2M-MONT · 1 kN (opens in a new tab) | PDF — K-S2M-MONT · 10 N (opens in a new tab) | PDF — K-S2M-MONT · 100 N (opens in a new tab) | PDF — K-S2M-MONT · 20 N (opens in a new tab) | PDF — K-S2M-MONT · 200 N (opens in a new tab) | PDF — K-S2M-MONT · 50 N (opens in a new tab) | PDF — K-S2M-MONT · 500 N (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
S2M measures tension and compression, with nominal capacities from 10 to 1000 N. These are separate capacity versions, not one sensor’s adjustable range.
The table specifies class 0.02 and separately lists repeatability, linearity, hysteresis and creep. It is not an uncertainty guarantee for every sensor/DAQ combination.
It uses a six-wire connection and 2 mV/V nominal sensitivity. Match a strain-gauge amplifier input, including the sense leads.
No. The datasheet gives −10 to +45°C nominal and −10 to +70°C operating. Operation does not establish identical specified performance throughout that wider interval.
The manufacturer documents a drag-chain-compatible cable and IP67 for the transducer. The drawing gives a 10 mm minimum bend radius; preserve the cable installation requirements.