Skip to content

S9M Force

S-beam strain-gauge sensor for compression and tension. Hermetically sealed to IP68, with passive mV/V output.

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for S9M
Ordering options and constraints K-S9M-MONT — capacity: 500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN; height_without_accessories: 2.44 in, 3.44 in, 3.94 in; diameter_without_cable_or_plug: 2.251964 in, 1.999996 in, 2.748026 in, 1.999996 in, 2.999994 in; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of S9M
Force range 0–2000 N
Nominal force capacity 500–50000 N

Models in the series

One column per model: what differs between the models of the series.

Models of S9M compared by parameter
Parameter 1-S9M/10KN-1 1-S9M/1KN-1 1-S9M/20KN-1 1-S9M/2KN-1 1-S9M/500N-1 1-S9M/50KN-1 1-S9M/5KN-1 K-S9M-MONT · 1 kN K-S9M-MONT · 10 kN K-S9M-MONT · 2 kN K-S9M-MONT · 20 kN K-S9M-MONT · 5 kN K-S9M-MONT · 50 kN K-S9M-MONT · 500 N
Load mode Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension Compression and tension
Protection class (DIN EN 60529) IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68
Force range 0–10000 N 0–1000 N 0–20000 N 0–2000 N 0–500 N 0–50000 N 0–5000 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate limited by system readout True True True True True True True Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Maximum capacity (nominal load): 10 kN; Height (without accessories): 3.44 in; Diameter (without cable or plug): 2.251964 in Maximum capacity (nominal load): 1 kN; Height (without accessories): 2.44 in; Diameter (without cable or plug): 1.999996 in Maximum capacity (nominal load): 20 kN; Height (without accessories): 3.94 in; Diameter (without cable or plug): 2.748026 in Maximum capacity (nominal load): 2 kN; Height (without accessories): 3.44 in; Diameter (without cable or plug): 2.251964 in Maximum capacity (nominal load): 500 N; Height (without accessories): 2.44 in; Diameter (without cable or plug): 1.999996 in Maximum capacity (nominal load): 50 kN; Height (without accessories): 3.94 in; Diameter (without cable or plug): 2.999994 in Maximum capacity (nominal load): 5 kN; Height (without accessories): 3.44 in; Diameter (without cable or plug): 2.251964 in Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Accuracy class ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩
Numeric manufacturer accuracy class 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1 kN nominal force capacity 10 kN nominal force capacity 2 kN nominal force capacity 20 kN nominal force capacity 5 kN nominal force capacity 50 kN nominal force capacity 500 N nominal force capacity
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1000 N 10000 N 2000 N 20000 N 5000 N 50000 N 500 N
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-S9M/10KN-1 (opens in a new tab) PDF — 1-S9M/1KN-1 (opens in a new tab) PDF — 1-S9M/20KN-1 (opens in a new tab) PDF — 1-S9M/2KN-1 (opens in a new tab) PDF — 1-S9M/500N-1 (opens in a new tab) PDF — 1-S9M/50KN-1 (opens in a new tab) PDF — 1-S9M/5KN-1 (opens in a new tab) PDF — K-S9M-MONT · 1 kN (opens in a new tab) PDF — K-S9M-MONT · 10 kN (opens in a new tab) PDF — K-S9M-MONT · 2 kN (opens in a new tab) PDF — K-S9M-MONT · 20 kN (opens in a new tab) PDF — K-S9M-MONT · 5 kN (opens in a new tab) PDF — K-S9M-MONT · 50 kN (opens in a new tab) PDF — K-S9M-MONT · 500 N (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Its table includes 0.5–50 kN versions for tension and compression. Select capacity together with the appropriate dimensions and force-introduction accessories.

The table specifies a 1 m water column for 100 hours. This does not establish suitability for every depth, duration or connection assembly.

No. Accuracy class, repeatability, linearity and hysteresis appear in separate rows. Preserve each definition and its measurement conditions.

No. The stated nominal range is −10 to +70°C and operating range −30 to +85°C. Evaluate performance within the interval to which each specification applies.

The documented version is a six-wire strain-gauge transducer with 2 mV/V sensitivity. It requires a compatible amplifier; mV/V must not be read as 0–10 V.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words