S9M Force
S-beam strain-gauge sensor for compression and tension. Hermetically sealed to IP68, with passive mV/V output.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-S9M-MONT — capacity: 500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN; height_without_accessories: 2.44 in, 3.44 in, 3.94 in; diameter_without_cable_or_plug: 2.251964 in, 1.999996 in, 2.748026 in, 1.999996 in, 2.999994 in; constraints: [] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–2000 N |
|---|---|
| Nominal force capacity | 500–50000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-S9M/10KN-1 | 1-S9M/1KN-1 | 1-S9M/20KN-1 | 1-S9M/2KN-1 | 1-S9M/500N-1 | 1-S9M/50KN-1 | 1-S9M/5KN-1 | K-S9M-MONT · 1 kN | K-S9M-MONT · 10 kN | K-S9M-MONT · 2 kN | K-S9M-MONT · 20 kN | K-S9M-MONT · 5 kN | K-S9M-MONT · 50 kN | K-S9M-MONT · 500 N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension |
| Protection class (DIN EN 60529) | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 | IP68 |
| Force range | 0–10000 N | 0–1000 N | 0–20000 N | 0–2000 N | 0–500 N | 0–50000 N | 0–5000 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Technical specification details | Maximum capacity (nominal load): 10 kN; Height (without accessories): 3.44 in; Diameter (without cable or plug): 2.251964 in | Maximum capacity (nominal load): 1 kN; Height (without accessories): 2.44 in; Diameter (without cable or plug): 1.999996 in | Maximum capacity (nominal load): 20 kN; Height (without accessories): 3.94 in; Diameter (without cable or plug): 2.748026 in | Maximum capacity (nominal load): 2 kN; Height (without accessories): 3.44 in; Diameter (without cable or plug): 2.251964 in | Maximum capacity (nominal load): 500 N; Height (without accessories): 2.44 in; Diameter (without cable or plug): 1.999996 in | Maximum capacity (nominal load): 50 kN; Height (without accessories): 3.94 in; Diameter (without cable or plug): 2.999994 in | Maximum capacity (nominal load): 5 kN; Height (without accessories): 3.44 in; Diameter (without cable or plug): 2.251964 in | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy class | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% |
| Numeric manufacturer accuracy class | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 kN nominal force capacity | 10 kN nominal force capacity | 2 kN nominal force capacity | 20 kN nominal force capacity | 5 kN nominal force capacity | 50 kN nominal force capacity | 500 N nominal force capacity |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000 N | 10000 N | 2000 N | 20000 N | 5000 N | 50000 N | 500 N |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-S9M/10KN-1 (opens in a new tab) | PDF — 1-S9M/1KN-1 (opens in a new tab) | PDF — 1-S9M/20KN-1 (opens in a new tab) | PDF — 1-S9M/2KN-1 (opens in a new tab) | PDF — 1-S9M/500N-1 (opens in a new tab) | PDF — 1-S9M/50KN-1 (opens in a new tab) | PDF — 1-S9M/5KN-1 (opens in a new tab) | PDF — K-S9M-MONT · 1 kN (opens in a new tab) | PDF — K-S9M-MONT · 10 kN (opens in a new tab) | PDF — K-S9M-MONT · 2 kN (opens in a new tab) | PDF — K-S9M-MONT · 20 kN (opens in a new tab) | PDF — K-S9M-MONT · 5 kN (opens in a new tab) | PDF — K-S9M-MONT · 50 kN (opens in a new tab) | PDF — K-S9M-MONT · 500 N (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Its table includes 0.5–50 kN versions for tension and compression. Select capacity together with the appropriate dimensions and force-introduction accessories.
The table specifies a 1 m water column for 100 hours. This does not establish suitability for every depth, duration or connection assembly.
No. Accuracy class, repeatability, linearity and hysteresis appear in separate rows. Preserve each definition and its measurement conditions.
No. The stated nominal range is −10 to +70°C and operating range −30 to +85°C. Evaluate performance within the interval to which each specification applies.
The documented version is a six-wire strain-gauge transducer with 2 mV/V sensitivity. It requires a compatible amplifier; mV/V must not be read as 0–10 V.
Get a quote or advice