Skip to content

T40FM Torque

Rotating torque flange for test benches with nominal torque ranges of 15–80 kN·m. Rated IP54.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of T40FM
Torque range -80000–80000 Nm
Maximum rotational speed 4500–8000 rpm
ADC sampling rate 1000–20000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of T40FM compared by parameter
Parameter T40FM T40FM-15kNm T40FM-20kNm T40FM-25kNm T40FM-30kNm T40FM-40kNm T40FM-50kNm T40FM-60kNm T40FM-70kNm T40FM-80kNm
Rotation Rotating Rotating Rotating Rotating Rotating Rotating Rotating Rotating Rotating Rotating
Mechanical connection Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange
Protection class (DIN EN 60529) IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54
Outputs and interfaces Unknown Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
Repeatability reference Family-level fallback: verify the ordered model and calibration certificate. "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData."
Sampling rate limited by system readout False Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Configurable family; exact public ordering-code table not exposed on the current HBK page. ±15 kNm rated torque; rotating installation; maximum 8,000 rpm ±20 kNm rated torque; rotating installation; maximum 8,000 rpm ±25 kNm rated torque; rotating installation; maximum 8,000 rpm ±30 kNm rated torque; rotating installation; maximum 6,000 rpm ±40 kNm rated torque; rotating installation; maximum 6,000 rpm ±50 kNm rated torque; rotating installation; maximum 6,000 rpm ±60 kNm rated torque; rotating installation; maximum 4,500 rpm ±70 kNm rated torque; rotating installation; maximum 4,500 rpm ±80 kNm rated torque; rotating installation; maximum 4,500 rpm
Rotational speed measurement True True True True True True True True True True
Linearity reference Family-level fallback: no unsupported scalar accuracy is added. "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData."
Sampling rate reference Use the exact configured transducer and HBK interface datasheets. TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors
Force range 15000–80000 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Torque range Not specified -15000–15000 Nm -20000–20000 Nm -25000–25000 Nm -30000–30000 Nm -40000–40000 Nm -50000–50000 Nm -60000–60000 Nm -70000–70000 Nm -80000–80000 Nm
Maximum rotational speed Not specified 8000 rpm 8000 rpm 8000 rpm 6000 rpm 6000 rpm 6000 rpm 4500 rpm 4500 rpm 4500 rpm
Operating temperature Not specified -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C
Interfaces Not specified EtherCAT PROFINET EtherCAT Ethernet Ethernet EtherCAT EtherCAT PROFINET Ethernet
ADC sampling rate Not specified 4000 samples/s 1000 samples/s 20000 samples/s 20000 samples/s 4000 samples/s 20000 samples/s 20000 samples/s 4000 samples/s 4000 samples/s
Status Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.

No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.

It lists 15–80 kN·m nominal-capacity versions in a short flange design. These are separate models requiring the corresponding connection geometry.

No. Up to 8000 rpm is marked as torque-range-dependent. Do not assign it to every capacity without the model table.

No. A speed/reference system with 1024 pulses/revolution is listed as an option. Select it when the application also needs speed or power calculation.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words