Skip to content

TB1A Torque

Non-rotating flange-mount torque reference disc. Stiff construction, central bore and IP54 protection.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of TB1A
Torque range -10000–10000 Nm
ADC sampling rate 450–40000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of TB1A compared by parameter
Parameter 1-TB1A/100NM 1-TB1A/10KNM 1-TB1A/1KNM 1-TB1A/200NM 1-TB1A/2KNM 1-TB1A/500NM 1-TB1A/5KNM TB1A-100Nm TB1A-10kNm TB1A-1kNm TB1A-200Nm TB1A-2kNm TB1A-500Nm TB1A-5kNm
Rotation Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating
Mechanical connection Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange
Protection class (DIN EN 60529) IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54
Torque range -100–100 Nm -10000–10000 Nm -1000–1000 Nm -200–200 Nm -2000–2000 Nm -500–500 Nm -5000–5000 Nm -100–100 Nm -10000–10000 Nm -1000–1000 Nm -200–200 Nm -2000–2000 Nm -500–500 Nm -5000–5000 Nm
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown RS422 / RS485 Digital I/O Analog 0-10V Analog 0-10V Analog 0-10V Digital I/O RS422 / RS485
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate limited by system readout False False False False False False False Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Actions: Not sellable online; Measurement range: 885 in-lb; Size (length): 3.94 in Actions: Not sellable online; Measurement range: 88507 in-lb; Size (length): 9.37 in Actions: Not sellable online; Measurement range: 8851 in-lb; Size (length): 6.14 in Actions: Not sellable online; Measurement range: 1770 in-lb; Size (length): 4.76 in Actions: Not sellable online; Measurement range: 17701 in-lb; Size (length): 7.52 in Actions: Not sellable online; Measurement range: 4425 in-lb; Size (length): 6.14 in Actions: Not sellable online; Measurement range: 44254 in-lb; Size (length): 9.37 in ±100 Nm rated torque; static / reaction installation ±10 kNm rated torque; static / reaction installation ±1 kNm rated torque; static / reaction installation ±200 Nm rated torque; static / reaction installation ±2 kNm rated torque; static / reaction installation ±500 Nm rated torque; static / reaction installation ±5 kNm rated torque; static / reaction installation
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. DMP41 selectable result rate, intended for reference and calibration measurements MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
Rotational speed measurement False False False False False False False False False False False False False False
Accuracy class ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩ ⁦0.05%⁩
Numeric manufacturer accuracy class 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Ethernet EtherCAT Ethernet Ethernet Ethernet EtherCAT Ethernet
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 %
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified 40000 samples/s 40000 samples/s 450 samples/s 40000 samples/s 19200 samples/s 40000 samples/s 19200 samples/s
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The manufacturer describes a low-profile reference transducer for torque measurement where space is limited. Select capacity and flange connections from the model drawing.

The table specifies 1.5 mV/V nominal sensitivity. Use compatible bridge electronics with excitation, rather than only an amplified industrial-voltage input.

No. Accuracy class, linearity including hysteresis and standard deviation of repeatability are separate properties with their own reference bases.

No. The manufacturer requires reduced limits when multiple irregular loads act together. Separate individual limits do not permit applying all maxima simultaneously.

The data sheet specifies IP54 according to EN 60529. Do not transfer another torque transducer protection rating to TB1A; also check the cable and connectors for the required installation conditions.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words