Skip to content

TN Torque

Non-rotating IP20 shaft torque transfer standard for calibration and metrology laboratories.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of TN
Torque range -20000–20000 Nm
ADC sampling rate 450–40000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of TN compared by parameter
Parameter 1-TN/100NM 1-TN/10KNM 1-TN/1KNM 1-TN/200NM 1-TN/20KNM 1-TN/2KNM 1-TN/500NM 1-TN/5KNM TN-100Nm TN-10kNm TN-1kNm TN-200Nm TN-20kNm TN-2kNm TN-500Nm TN-5kNm
Rotation Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating
Mechanical connection Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft
Protection class (DIN EN 60529) IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20
Technical specification details Actions: Not sellable online; Measurement range: 885 in-lb; Size (length): 10.1 in Actions: Not sellable online; Measurement range: 88507 in-lb; Size (length): 20.5 in Actions: Not sellable online; Measurement range: 8851 in-lb; Size (length): 10.1 in Actions: Not sellable online; Measurement range: 1770 in-lb; Size (length): 10.1 in Actions: Not sellable online; Measurement range: 177015 in-lb; Size (length): 20.5 in Actions: Not sellable online; Measurement range: 17701 in-lb; Size (length): 13.8 in Actions: Not sellable online; Measurement range: 4425 in-lb; Size (length): 10.1 in Actions: Not sellable online; Measurement range: 44254 in-lb; Size (length): 15.6 in ±100 Nm rated torque; static / reaction installation ±10 kNm rated torque; static / reaction installation ±1 kNm rated torque; static / reaction installation ±200 Nm rated torque; static / reaction installation ±20 kNm rated torque; static / reaction installation ±2 kNm rated torque; static / reaction installation ±500 Nm rated torque; static / reaction installation ±5 kNm rated torque; static / reaction installation
Torque range -100–100 Nm -10000–10000 Nm -1000–1000 Nm -200–200 Nm -20000–20000 Nm -2000–2000 Nm -500–500 Nm -5000–5000 Nm -100–100 Nm -10000–10000 Nm -1000–1000 Nm -200–200 Nm -20000–20000 Nm -2000–2000 Nm -500–500 Nm -5000–5000 Nm
Rotational speed measurement False False False False False False False False False False False False False False False False
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth DMP41 selectable result rate, intended for reference and calibration measurements
Sampling rate limited by system readout False False False False False False False False Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Analog 0-10V Digital I/O Analog 0-10V Analog 0-10V RS422 / RS485 Analog 0-10V Digital I/O Analog 0-10V
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Accuracy class ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩ ⁦0.02%⁩
Numeric manufacturer accuracy class 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 450 samples/s 40000 samples/s 19200 samples/s 40000 samples/s 19200 samples/s 40000 samples/s 40000 samples/s 19200 samples/s
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0.02 % 0.02 % 0.02 % 0.02 % 0.02 % 0.02 % 0.02 % 0.02 %
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified EtherCAT Ethernet Ethernet Ethernet EtherCAT Ethernet PROFINET Ethernet
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

TN is a torque transfer standard for reference use in calibration machines and laboratory accreditation. It is not described as a high-speed rotating telemetry flange.

The manufacturer links DIN 51309 Class 0.05 to the corresponding DAkkS/DKD calibration certificate. Preserve that certificate qualification.

Mbx and Mby bridges check force introduction and parasitic bending moments. Their presence does not make TN a six-axis transducer.

It uses cylindrical shaft ends without keys, dimensioned to DIN 51309. Select adapters for the capacity and connection drawing.

The data sheet distinguishes a nominal range of +10 to +30 °C from an operating range of +10 to +40 °C. Include temperature effects in the uncertainty budget for reference work; operability does not guarantee identical uncertainty across the entire range.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words