TOP Transfer Force
TOP Transfer: sensors and measurement devices by HBK for force.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | -500000–500000 N |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | TOP Transfer-100000N | TOP Transfer-10000N | TOP Transfer-1000N | TOP Transfer-100N | TOP Transfer-200000N | TOP Transfer-20000N | TOP Transfer-2000N | TOP Transfer-200N | TOP Transfer-500000N | TOP Transfer-50000N | TOP Transfer-5000N | TOP Transfer-500N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Technical specification details | 100000 N rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression and tension | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression and tension | 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression and tension | 100 N rated capacity = 100 N (10.1972 kg mass equivalent at standard gravity); compression and tension | 200000 N rated capacity = 200 kN (20.3943 t mass equivalent at standard gravity); compression and tension | 20000 N rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression and tension | 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression and tension | 200 N rated capacity = 200 N (20.3943 kg mass equivalent at standard gravity); compression and tension | 500000 N rated capacity = 500 kN (50.9858 t mass equivalent at standard gravity); compression and tension | 50000 N rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression and tension | 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression and tension | 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression and tension |
| Force range | -100000–100000 N | -10000–10000 N | -1000–1000 N | -100–100 N | -200000–200000 N | -20000–20000 N | -2000–2000 N | -200–200 N | -500000–500000 N | -50000–50000 N | -5000–5000 N | -500–500 N |
| Accuracy (% FSO) | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % | 0.015 % |
| Interfaces | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet |
| Outputs and interfaces | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 |
| Sampling rate reference | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements |
| ADC sampling rate | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s | 450 samples/s |
| Accuracy class | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% | 0.015% |
| Numeric manufacturer accuracy class | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 | 0.015 |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — TOP Transfer-100000N (opens in a new tab) | PDF — TOP Transfer-10000N (opens in a new tab) | PDF — TOP Transfer-1000N (opens in a new tab) | PDF — TOP Transfer-100N (opens in a new tab) | PDF — TOP Transfer-200000N (opens in a new tab) | PDF — TOP Transfer-20000N (opens in a new tab) | PDF — TOP Transfer-2000N (opens in a new tab) | PDF — TOP Transfer-200N (opens in a new tab) | PDF — TOP Transfer-500000N (opens in a new tab) | PDF — TOP Transfer-50000N (opens in a new tab) | PDF — TOP Transfer-5000N (opens in a new tab) | PDF — TOP Transfer-500N (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Tensile and compressive force for high-precision comparison and calibration.
100 N to 500 kN across the available models.
The manufacturer lists ISO 376 Class 00 and HBK class 0.015; these are distinct classifications.
HBK recommends DMP41 for a precision measurement chain.
Yes. HBK recommends calibrating the transducer, amplifier and load fittings together.
Get a quote or advice
Tell us what you need and an engineer will come back to you.