TTS Torque
Non-rotating torque transfer wrench with square-drive adapters and IP22 protection. Designed for torque-wrench calibration.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Torque range | -1000–1000 Nm |
|---|---|
| ADC sampling rate | 450–19200 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-TTS/1000NM | 1-TTS/100NM | 1-TTS/200NM | 1-TTS/500NM | TTS-100Nm | TTS-1kNm | TTS-200Nm | TTS-500Nm |
|---|---|---|---|---|---|---|---|---|
| Rotation | Non-rotating | Non-rotating | Non-rotating | Non-rotating | Non-rotating | Non-rotating | Non-rotating | Non-rotating |
| Mechanical connection | Shaft | Shaft | Shaft | Shaft | Shaft | Shaft | Shaft | Shaft |
| Rotational speed measurement | False | False | False | False | False | False | False | False |
| Sampling rate limited by system readout | False | False | False | False | Not specified | Not specified | Not specified | Not specified |
| Technical specification details | Actions: Not sellable online; Measurement range: 8851 in-lb; Size (length): 37 in | Actions: Not sellable online; Measurement range: 885 in-lb; Size (length): 19.5 in | Actions: Not sellable online; Measurement range: 1770 in-lb; Size (length): 27.2 in | Actions: Not sellable online; Measurement range: 4425 in-lb; Size (length): 37 in | ±100 Nm rated torque; static / reaction installation | ±1 kNm rated torque; static / reaction installation | ±200 Nm rated torque; static / reaction installation | ±500 Nm rated torque; static / reaction installation |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Analog 0-10V | Analog 0-10V | Digital I/O | RS422 / RS485 |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified |
| Torque range | -1000–1000 Nm | -100–100 Nm | -200–200 Nm | -500–500 Nm | -100–100 Nm | -1000–1000 Nm | -200–200 Nm | -500–500 Nm |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | 19200 samples/s | 19200 samples/s | 19200 samples/s | 450 samples/s |
| Interfaces | Not specified | Not specified | Not specified | Not specified | EtherCAT | PROFINET | Ethernet | Ethernet |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | 0.5 % | 0.5 % | 0.5 % | 0.5 % |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
TTS is a transfer transducer for calibrating torque-wrench calibration devices. It serves a reference chain rather than merely tightening fasteners.
No. The datasheet states that the DKD certificate is not supplied as standard and must be ordered separately. Transfer-transducer classification is established through that certificate.
No. The manufacturer qualifies some values by the supplied square adapter and its fixing. Changing it requires rechecking measurement conditions.
No. The table distinguishes reproducibility across mounting positions and across lever lengths. Preserve the applicable test conditions.
No. The reference sensitivity is 1.5 mV/V, but the documented sensitivity range is 1.5–2.4 mV/V. For accurate measurement, use the individual transducer sensitivity established by calibration rather than one common reference value.
Get a quote or advice
Tell us what you need and an engineer will come back to you.