Skip to content

TTS Torque

Non-rotating torque transfer wrench with square-drive adapters and IP22 protection. Designed for torque-wrench calibration.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of TTS
Torque range -1000–1000 Nm
ADC sampling rate 450–19200 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of TTS compared by parameter
Parameter 1-TTS/1000NM 1-TTS/100NM 1-TTS/200NM 1-TTS/500NM TTS-100Nm TTS-1kNm TTS-200Nm TTS-500Nm
Rotation Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating Non-rotating
Mechanical connection Shaft Shaft Shaft Shaft Shaft Shaft Shaft Shaft
Rotational speed measurement False False False False False False False False
Sampling rate limited by system readout False False False False Not specified Not specified Not specified Not specified
Technical specification details Actions: Not sellable online; Measurement range: 8851 in-lb; Size (length): 37 in Actions: Not sellable online; Measurement range: 885 in-lb; Size (length): 19.5 in Actions: Not sellable online; Measurement range: 1770 in-lb; Size (length): 27.2 in Actions: Not sellable online; Measurement range: 4425 in-lb; Size (length): 37 in ±100 Nm rated torque; static / reaction installation ±1 kNm rated torque; static / reaction installation ±200 Nm rated torque; static / reaction installation ±500 Nm rated torque; static / reaction installation
Outputs and interfaces Unknown Unknown Unknown Unknown Analog 0-10V Analog 0-10V Digital I/O RS422 / RS485
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified Not specified Not specified Not specified
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified
Torque range -1000–1000 Nm -100–100 Nm -200–200 Nm -500–500 Nm -100–100 Nm -1000–1000 Nm -200–200 Nm -500–500 Nm
ADC sampling rate Not specified Not specified Not specified Not specified 19200 samples/s 19200 samples/s 19200 samples/s 450 samples/s
Interfaces Not specified Not specified Not specified Not specified EtherCAT PROFINET Ethernet Ethernet
Accuracy (% FSO) Not specified Not specified Not specified Not specified 0.5 % 0.5 % 0.5 % 0.5 %
Status Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

TTS is a transfer transducer for calibrating torque-wrench calibration devices. It serves a reference chain rather than merely tightening fasteners.

No. The datasheet states that the DKD certificate is not supplied as standard and must be ordered separately. Transfer-transducer classification is established through that certificate.

No. The manufacturer qualifies some values by the supplied square adapter and its fixing. Changing it requires rechecking measurement conditions.

No. The table distinguishes reproducibility across mounting positions and across lever lengths. Preserve the applicable test conditions.

No. The reference sensitivity is 1.5 mV/V, but the documented sensitivity range is 1.5–2.4 mV/V. For accurate measurement, use the individual transducer sensitivity established by calibration rather than one common reference value.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words