1-U10M/250KN

From the U10M series

Strain-gauge transducer for alternating compression and tension in fatigue testing. Available with mV/V or an integrated IO-Link amplifier. A cable option can achieve IP68.

Force range
-250000–250000 N
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for 1-U10M/250KN
Accuracy class ⁦0.04%⁩
Outputs and interfaces Unknown
Pressure sensor output mV/V (passive strain gauge)
Technical specification details Maximum capacity (nominal load): 250 kN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Both sides central internal thread; Height (without accessories): 2.5 in; Diameter (without cable or plug): 7.999984 in
Ordering options and constraints K-U10M — capacity: 1.25 kN, 2.5 kN, 5 kN, 12.5 kN, 25 kN, 50 kN, 125 kN, 250 kN, 500 kN, 1.25 MN; bridge: SB, DB; rated_output: N, J; calibration: 100%, 200%; teds: Not selected, T; mechanical_design: W adapter, N flange; plug_protection: P, U; electrical_connection: B, G, K (6 m), V (15 m), 00A4 (VAIO); force_application: O, L; cable_plug: Y, F, Q, N, P, M, X; integrated_amplifier: N, VAIO; constraints: [{"when": {"teds": "T"}, "deny": {"integrated_amplifier": ["VAIO"]}, "reason": "TEDS and the integrated VAIO amplifier are mutually exclusive in the official configuration."}, {"when": {"integrated_amplifier": "VAIO"}, "allow": {"electrical_connection": "00A4 (VAIO)"}, "reason": "The VAIO connection is reserved for the integrated-amplifier option."}]
Load mode Compression and tension
Sampling rate limited by system readout True
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate.
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred.
Linearity reference No single accuracy class is inferred when it is not shown for the exact ordering code.

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Force range -250000–250000 N
Force range 0–250000 N