Z30A Force
Reference transducer for force calibration and precision measurements. HBK offers compression, tension or combined calibration, depending on configuration.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | -10000–10000 N |
|---|---|
| ADC sampling rate | 450–40000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-Z30A/1000N | 1-Z30A/100N | 1-Z30A/10KN | 1-Z30A/200N | 1-Z30A/2KN | 1-Z30A/500N | 1-Z30A/50N | 1-Z30A/5KN | Z30A-10000N | Z30A-1000N | Z30A-100N | Z30A-2000N | Z30A-200N | Z30A-5000N | Z30A-500N | Z30A-50N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Force range | 0–1000 N | 0–100 N | 0–10000 N | 0–200 N | 0–2000 N | 0–500 N | 0–50 N | 0–5000 N | -10000–10000 N | -1000–1000 N | -100–100 N | -2000–2000 N | -200–200 N | -5000–5000 N | -500–500 N | -50–50 N |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | RS422 / RS485 | Analog 0-10V | RS422 / RS485 | Digital I/O | Analog 0-10V | Digital I/O | RS422 / RS485 | Analog 0-10V |
| Technical specification details | Maximum capacity (nominal load): 1 kN | Maximum capacity (nominal load): 100 N | Maximum capacity (nominal load): 10 kN | Maximum capacity (nominal load): 200 N | Maximum capacity (nominal load): 2 kN | Maximum capacity (nominal load): 500 N | Maximum capacity (nominal load): 50 N | Maximum capacity (nominal load): 5 kN | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression and tension | 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression and tension | 100 N rated capacity = 100 N (10.1972 kg mass equivalent at standard gravity); compression and tension | 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression and tension | 200 N rated capacity = 200 N (20.3943 kg mass equivalent at standard gravity); compression and tension | 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression and tension | 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression and tension | 50 N rated capacity = 50 N (5.0986 kg mass equivalent at standard gravity); compression and tension |
| Accuracy class | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% | 0.02% |
| Numeric manufacturer accuracy class | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Ethernet | Ethernet | PROFINET | Ethernet | PROFINET | Ethernet | Ethernet | Ethernet |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 40000 samples/s | 19200 samples/s | 450 samples/s | 40000 samples/s | 450 samples/s | 40000 samples/s | 19200 samples/s | 19200 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-Z30A/1000N (opens in a new tab) | PDF — 1-Z30A/100N (opens in a new tab) | PDF — 1-Z30A/10KN (opens in a new tab) | PDF — 1-Z30A/200N (opens in a new tab) | PDF — 1-Z30A/2KN (opens in a new tab) | PDF — 1-Z30A/500N (opens in a new tab) | PDF — 1-Z30A/50N (opens in a new tab) | PDF — 1-Z30A/5KN (opens in a new tab) | PDF — Z30A-10000N (opens in a new tab) | PDF — Z30A-1000N (opens in a new tab) | PDF — Z30A-100N (opens in a new tab) | PDF — Z30A-2000N (opens in a new tab) | PDF — Z30A-200N (opens in a new tab) | PDF — Z30A-5000N (opens in a new tab) | PDF — Z30A-500N (opens in a new tab) | PDF — Z30A-50N (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. The specified stop applies only up to 1000 N nominal force. Do not assume it exists on 2–10 kN models.
Z30A is a reference transducer for small tensile/compressive forces, calibration-machine verification and transfer measurements. Match calibration to the required force direction.
Yes. The manufacturer specifies integrated TEDS transducer identification for Z30A.
No. It also serves as a working standard and transfer transducer for calibration-machine verification and measurement traceability.
Housing and base connections allow cable routing suited to the installation and help avoid forces transmitted by the cable into the measurement. This matters particularly for small forces; select the connection for the force-introduction arrangement.