Skip to content

TYPE 4375

Type 4375 is designed for high-frequency vibration measurements on light components. Its integral cable can be routed and secured with the sensor in a permanent installation. The 4375-V variant has a different tolerance around the nominal sensitivity.

Visit the HBK site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of TYPE 4375 compared by parameter
Parameter -4375— -4375--- -4375-V– -4375-V--
Acceleration sensitivity 3.1 mV/g 3.1 mV/g
Technical specification details ±5000 g indexed capacity; Uniaxial; Miniature/ESS; Stud mounting ±5000 g indexed capacity; Uniaxial; Miniature/ESS; Stud mounting
Outputs and interfaces Unknown Unknown
Sampling rate limited by system readout True Not specified
Static (DC) acceleration measurement False Not specified
Operating temperature -74–288 °C -74–288 °C
Number of measurement channels 1 1
Vibration sensor output Piezoelectric charge; Analogue Not specified
Repeatability reference HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. Not specified
Sampling rate reference Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Not specified
Number of axes 1 1
Linearity reference Official indexed sensitivity tolerance: 2%. Not specified
Frequency response 0–60000 kHz 0–60000 kHz
Status Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The specified band is 0.1 Hz to 16.5 kHz at the ±10% amplitude limit. Installed response also depends on the mechanical interface and charge amplifier.

The sensor mounts with an M3 stud. Leave a route for the side cable and secure it so it does not pull on the light sensor body.

Choose 4375 when an integral cable suits the setup, for example in a permanent installation on a lightweight part. The 4393 has a side socket for a detachable cable.

Both are nominally 3.10 pC/g at 159.2 Hz. Sensitivity tolerance is ±2% for 4375 and ±15% for 4375-V.

Mounted resonance is 55 kHz. The vibration measurement band at the ±10% amplitude limit extends to 16.5 kHz.

Didn't find the answer you were looking for?