confocalDT IFD2411

The confocalDT IFD2411 system combines an IFC2411 controller with an IFS2404 sensor connected by optical fiber. This arrangement allows the sensor head to be positioned separately from the controller. The sensor calibration table must be stored in the controller; measuring range and interfaces depend on the model and configuration.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of confocalDT IFD2411
Linearity 0.5–3 µm
Accuracy 0.5–3 µm
Measuring range 1–6 mm

Models in the series

One column per model: what differs between the models of the series.

Models of confocalDT IFD2411 compared by parameter
Parameter IFD2411-1 IFD2411-2 IFD2411-3 IFD2411-6 IFD2411/90-2
Number of measurement channels 1 1 1 1 1
Contact Non-contact Non-contact Non-contact Non-contact Non-contact
Measuring rate 8 kHz 8 kHz 8 kHz 8 kHz 8 kHz
Linearity 0.5 µm 1 µm 1.5 µm 3 µm 1 µm
Accuracy 0.5 µm 1 µm 1.5 µm 3 µm 1 µm
Measuring range 1 mm 2 mm 3 mm 6 mm 2 mm
Status Active Active Active Active Active
Datasheet PDF — IFD2411-1 (opens in a new tab) PDF — IFD2411-2 (opens in a new tab) PDF — IFD2411-3 (opens in a new tab) PDF — IFD2411-6 (opens in a new tab) PDF — IFD2411/90-2 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The described system has a matched head and compact controller connected by optical fiber. It differs from the all-in-one IFD2410/IFD2415 architecture.

The table defines 100 Hz to 8 kHz. Static resolution uses 512-value averaging at 1 kHz, so retain separate performance conditions.

No. The table specifies sensor IP64 and controller IP40. Assess environmental conditions for each component.

It lists 1, 2, 3 and 6 mm, including a /90 version at 2 mm. Start distance and light spot depend on the model.

The cited table specifies one layer. Multilayer work requires a configuration explicitly supporting the required layer count.

Didn't find the answer you were looking for?

Talk to an expert