eddyNCDT controller components Inductive (eddy current)
eddyNCDT controller components: measurement controllers by Micro-Epsilon for inductive (eddy current).
Visit the Micro-Epsilon site (opens in a new tab)Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Linearity (% FSO) | 0.1–0.2 % |
|---|---|
| Static resolution (% FSO) | 0.002–0.005 % |
| Dynamic resolution (% FSO) | 0.01–0.2 % |
| Supply voltage | 11–32 V |
| Operating temperature | 0–50 °C |
| Number of characteristic curves | 1–4 |
| Current consumption | 420–700 mA |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | DT3060 | DT3061 | DT3300 | DT3301 |
|---|---|---|---|---|
| Number of measurement channels | 1 | 1 | 1 | 1 |
| Interfaces | Ethernet | Ethernet | Not specified | Not specified |
| Linearity (% FSO) | < ±0.2 % FSO; matched sensor/controller, 3-/5-point linearization | < ±0.1 % FSO; matched sensor/controller, 3-/5-point linearization | < ±0.2 % FSO | < ±0.2 % FSO |
| Measuring rate, analog output | 200 kHz | 200 kHz | Not specified | Not specified |
| Measuring rate, digital interface | 50 kHz | 50 kHz | Not specified | Not specified |
| Static resolution (% FSO) | 0.002 % FSO (RMS; reference: midrange; 20 Hz) | 0.002 % FSO (RMS; reference: midrange; 20 Hz) | 0.005 % FSO (peak-to-peak; 25 Hz) | 0.005 % FSO (peak-to-peak; 25 Hz) |
| Dynamic resolution (% FSO) | 0.01 % FSO (RMS; reference: midrange; 20 kHz) | 0.01 % FSO (RMS; reference: midrange; 20 kHz) | 0.2 % FSO (peak-to-peak) | 0.2 % FSO (peak-to-peak) |
| Frequency response cutoff Maximum rate with a compatible controller | 20 kHz | 20 kHz | Not specified | Not specified |
| Protection class (DIN EN 60529) | IP67 (plugged) | IP67 (plugged) | IP64 | IP64 |
| Supply voltage | 12 V / 32 V | 12 V / 32 V | Not specified | 11 V / 32 V |
| Operating temperature | 0 °C / 50 °C | 0 °C / 50 °C | 5 °C / 50 °C | 5 °C / 50 °C |
| Storage temperature | -10 °C / 70 °C | -10 °C / 70 °C | Not specified | Not specified |
| Temperature compensation | 10 °C / 50 °C | 10 °C / 50 °C | Not specified | Not specified |
| Controller temperature stability (% FSO/K) | < 0.015 % FSO/K (midrange; compensated temperature range) | < 0.015 % FSO/K (midrange; compensated temperature range) | Not specified | Not specified |
| Number of characteristic curves | 1 | 4 | 3 | 3 |
| Analog output resolution | 16 bit | 16 bit | Not specified | Not specified |
| Digital output resolution | 16 bit | 16 bit | Not specified | Not specified |
| Selectable frequency response | 20 / 5000 / 20000 | 20 / 5000 / 20000 | 25 Hz; 2.5 kHz; 25 kHz; 100 kHz only for measuring span ≤1 mm | 25 Hz; 2.5 kHz; 25 kHz; 100 kHz only for measuring span ≤1 mm |
| Weight | approx. 230 g | approx. 230 g | Not specified | Not specified |
| Analog current output | 4–20 mA | 4–20 mA | Not specified | Not specified |
| Analog voltage output | 0–10 V | 0–10 V | Not specified | Not specified |
| Power consumption, typical | 2.5 W | 2.5 W | Not specified | Not specified |
| Power consumption, maximum | 2.8 W | 2.8 W | Not specified | Not specified |
| Channels | 1 | 1 | 1 | 1 |
| Analog voltage output range | 0–10 V | 0–10 V | Not specified | Not specified |
| Analog current output range | 4–20 mA | 4–20 mA | Not specified | Not specified |
| Resolution (% FSO) | Not specified | Not specified | 0.005 % | 0.005 % |
| Adaptation board required | Not specified | Not specified | Yes | Yes |
| Current consumption | Not specified | Not specified | 420 mA | 700 mA |
| Calibration after configuration changes | Not specified | Not specified | Yes | Yes |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — DT3060 (opens in a new tab) | PDF — DT3061 (opens in a new tab) | PDF — DT3300 (opens in a new tab) | PDF — DT3301 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Check head compatibility, target material, calibration, bandwidth and interface. Connector compatibility alone does not establish system performance.
No. Resolution and linearity are separate specifications with different conditions. Preserve linearization requirements and the resolution bandwidth.
No. DT306x/307x provide Ethernet; DT3005/DT3020 use RS485 and need an adapter for Ethernet. Check the exact controller.
Match voltage, power, pin count, wiring and cable function. The catalogue distinguishes PCx/5-M12, PCx/8-M12 and signal versus network cables.
No. Head, controller, cable and adapter can have different limits. Each must satisfy the conditions at its installation location.
Get a quote or advice