Skip to content

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for DT3020
Linearity (% FSO) < ±0.2 % FSO; matched sensor/controller, 3-/5-point linearization
Supply voltage 12 V / 32 V
Interfaces RS-485
Storage temperature -20 °C / 105 °C
Operating temperature -20–105 °C
Protection class (DIN EN 60529) IP67
Frequency response 10–5000 Hz
Controller temperature stability (% FSO/K) < 0.025 % FSO/K (midrange; compensated temperature range)
Measuring rate, analog output 80 kHz
Measuring rate, digital interface 10 kHz
Static resolution (% FSO) 0.004 % FSO (RMS; reference: midrange; 20 Hz)
Dynamic resolution (% FSO) 0.01 % FSO (RMS; reference: midrange; 5 kHz)
Frequency response cutoff Maximum rate with a compatible controller 5 kHz
Channels 1
Interfaces via separate adapter usb / ethernet / ethercat / profinet / ethernet_ip
Temperature compensation 10 °C / 105 °C
Maximum current-output load 500 Ω
Switching output modes NPN / PNP / push-pull
Number of characteristic curves 1
Weight approx. 190 g

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Dimension (drawing reference) 53 mm
Dimension (drawing reference) 76 mm
Dimension (drawing reference) 102 mm
Dimension (drawing reference) 30 mm
Resolution (% FSO) 0.004 %
Resolution (% FSO) 0.01 %
Request a quote for this product

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words