| Measuring range | 3.5 mm |
|---|---|
| Start of measuring range | 1.9 mm |
| Light spot diameter | 0.02 mm |
| Maximum measuring angle | 3 deg |
| Numerical aperture (NA) | 0.1 |
| Storage temperature | -20–70 °C |
| Operating temperature | 5–70 °C |
| Protection class (DIN EN 60529) | IP64 |
| Weight | 0.186 kg |
| Mounting | Radial clamping (mounting adapter see accessories) |
| Target material | reflective, diffuse as well as transparent surfaces (e.g. glass) |
| Measurement restrictions | Official printed order code says -4 while published measuring range is 3.5 mm. Kept source-only; internal catalog aliases this range as IFS2402-3.5. Do not join without model-code approval. |
| Contact | Non-contact |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Resolution | 0.48 µm |
|---|---|
| Resolution | 0.05 µm |
Compatible system components
Controllers
-
IFC2411
Required
- Measuring rate
- 8 kHz
- Communication
- Ethernet, RS422
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2411/IE
Required
- Measuring rate
- 8 kHz
- Communication
- RS422, PROFINET, EtherNet/IP, EtherCAT
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2412
Required
- Measuring rate
- 8 kHz
- Communication
- RS422, Ethernet
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2412/IE
Required
- Measuring rate
- 8 kHz
- Communication
- EtherCAT, RS422
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2416
Required
- Measuring rate
- 25 kHz
- Communication
- Ethernet, RS422
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2417
Required
- Measuring rate
- 25 kHz
- Communication
- RS422, Ethernet
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2417/IE
Required
- Measuring rate
- 25 kHz
- Communication
- EtherCAT, RS422
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2421
Required
- Measuring rate
- 10 kHz
- Communication
- Ethernet, RS422, EtherCAT
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2421MP
Required
- Measuring rate
- 10 kHz
- Communication
- EtherCAT, Ethernet, RS422
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2422
Required
- Measuring rate
- 10 kHz
- Communication
- EtherCAT, Ethernet, RS422
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2422MP
Required
- Measuring rate
- 10 kHz
- Communication
- Ethernet, EtherCAT, RS422
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2465
Required
- Measuring rate
- 30 kHz
- Communication
- Ethernet, EtherCAT, RS422
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2465MP
Required
- Measuring rate
- 30 kHz
- Communication
- EtherCAT, RS422, Ethernet
- Inputs
- 1
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2466
Required
- Measuring rate
- 30 kHz
- Communication
- EtherCAT, Ethernet, RS422
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
-
IFC2466MP
Required
- Measuring rate
- 30 kHz
- Communication
- RS422, Ethernet, EtherCAT
- Inputs
- 2
- Signal type
- Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
Compatible accessories
Optical fibres
Power supplies
-
PS2020 (2420062)
Optional
Mounting
-
MA2402
Optional
Accessories
-
C2402/Vac/KF16
Optional
-
C2405/Vac/1/KF16
Optional
-
C2405/Vac/1/CF16
Optional
-
C2405/Vac/6/CF63
Optional
Complementary products
-
IF1032/ETH
Optional
-
IF2001/USB
Optional
-
IF2004/USB
Optional
-
IF2008/PCIE
Optional
-
IF2008/ETH
Optional
-
IFL2422/LED
Optional
- IFL24x1/LED configurable component family Optional Only for source configuration configuration-1dbb12dc48cee094978b4167: IFS2402-4; selected configuration must be matched before display.
Cables
-
SC2415-x/IF2008
Optional
-
SC2415-x/IF2008ETH
Optional
-
SC2415-x/OE
Optional
-
SC2471-x/IF2008
Optional
-
SC2471-3/IF2008ETH
Optional
-
SC2471-x/RS422/OE
Optional
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The measuring span is 3.5 mm and starts approximately 1.9 mm from the sensor face. Position the target so that the expected motion stays within the window.
The datasheet specifies less than 480 nm RMS noise at mid-span at a 1 kHz measuring rate. This value describes noise under the specified test conditions.
Micro-Epsilon lists a 3.5 mm measuring span for this model. The beam travels along the sensor axis.
Get a quote or advice
Tell us what you need and an engineer will come back to you.