Skip to content

IFS2402/90-4

From the IFS2402 series

4 mm confocal heads for distance and displacement measurement in bores and confined spaces. Axial and radial beam versions are available.

Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for IFS2402/90-4
Measuring range 3.5 mm
Start of measuring range 2.5 mm
Light spot diameter 0.02 mm
Maximum measuring angle 3 deg
Numerical aperture (NA) 0.1
Storage temperature -20–70 °C
Operating temperature 5–70 °C
Protection class (DIN EN 60529) IP40
Weight 0.186 kg
Mounting Radial clamping (mounting adapter see accessories)
Target material reflective, diffuse as well as transparent surfaces (e.g. glass)
Measurement restrictions Official printed order code says /90-4 while published measuring range is 3.5 mm. Kept source-only; internal catalog aliases this range as IFS2402/90-3.5. Do not join without model-code approval.
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Resolution 0.48 µm
Resolution 0.05 µm
Request a quote for this product

Compatible system components

Controllers

  • IFC2411 Required
    Measuring rate
    8 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2411/IE Required
    Measuring rate
    8 kHz
    Communication
    RS422, PROFINET, EtherNet/IP, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412 Required
    Measuring rate
    8 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412/IE Required
    Measuring rate
    8 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2416 Required
    Measuring rate
    25 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417 Required
    Measuring rate
    25 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417/IE Required
    Measuring rate
    25 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421 Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, RS422, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421MP Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422 Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422MP Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465 Required
    Measuring rate
    30 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465MP Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, RS422, Ethernet
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466 Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466MP Required
    Measuring rate
    30 kHz
    Communication
    RS422, Ethernet, EtherCAT
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The measuring span is 3.5 mm and starts approximately 2.5 mm from the sensor axis. Position the target so that the expected motion stays within the window.

The datasheet specifies less than 480 nm RMS noise at mid-span at a 1 kHz measuring rate. This value describes noise under the specified test conditions.

Micro-Epsilon lists a 3.5 mm measuring span for this model. The radial beam can read a bore wall from the side.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words