Skip to content

IFS2405-3

From the IFS2405 series

Confocal heads for distance and one-sided transparent thickness measurement across a choice of spans. Dedicated vacuum versions are available.

Number of measurement channels
2
Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for IFS2405-3
Measuring range 3 mm
Start of measuring range 20 mm
Working distance 5–30 mm
Linearity 0.6 µm
Light spot diameter 0.009 mm
Maximum measuring angle 24 deg
Numerical aperture (NA) 0.45
Storage temperature -20–70 °C
Operating temperature 5–70 °C
Weight 0.225 kg
Mounting Radial clamping (mounting adapter see accessories)
Technical specification details 3 mm net measuring range
Accuracy 0.9 µm
Minimum target thickness 0.15 mm
Target material reflective, diffuse as well as transparent surfaces (e.g. glass)
Linearity reference https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity.
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces EtherCAT
Interfaces Ethernet
Interfaces PROFINET
Number of measurement channels 2
Number of measurement channels 1
Outputs and interfaces RS422 / RS485
Outputs and interfaces Analog 0-10V
Outputs and interfaces Digital I/O
Outputs and interfaces 4-20mA
Protection class (DIN EN 60529) IP40
Protection class (DIN EN 60529) IP64
Resolution 0.008 µm
Resolution 0.08 µm
Sampling rate reference IFC2417: 25,000 measurements/s per synchronous channel
Sampling rate reference IFC2421: 10,000 measurements/s
Sampling rate reference IFC2422MP: 10,000 measurements/s per synchronous channel
Sampling rate reference IFC2412: 8,000 measurements/s per synchronous channel
Sampling rate reference IFC2421MP: 10,000 measurements/s
Sampling rate reference IFC2411: 8,000 measurements/s
Sampling rate reference IFC2466MP: 30,000 measurements/s per synchronous channel
Sampling rate reference IFC2422: 10,000 measurements/s per synchronous channel
Sampling rate reference IFC2465MP: 30,000 measurements/s
Sampling rate reference IFC2416: 25,000 measurements/s
Sampling rate reference IFC2466: 30,000 measurements/s per synchronous channel
Sampling rate reference IFC2465: 30,000 measurements/s
Request a quote for this product

Compatible system components

Controllers

  • IFC2411 Required
    Measuring rate
    8 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2411/IE Required
    Measuring rate
    8 kHz
    Communication
    RS422, PROFINET, EtherNet/IP, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412 Required
    Measuring rate
    8 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412/IE Required
    Measuring rate
    8 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2416 Required
    Measuring rate
    25 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417 Required
    Measuring rate
    25 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417/IE Required
    Measuring rate
    25 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421 Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, RS422, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421MP Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422 Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422MP Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465 Required
    Measuring rate
    30 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465MP Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, RS422, Ethernet
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466 Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466MP Required
    Measuring rate
    30 kHz
    Communication
    RS422, Ethernet, EtherCAT
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)

Compatible accessories

Optical fibres

Power supplies

Mounting

Accessories

Complementary products

Cables

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The measuring span is 3 mm. It starts approximately 20 mm from the sensor face, putting the far end of the window at approximately 23 mm.

Compare the material thickness and refractive index with the model’s stated conditions. The manufacturer’s minimum-thickness example uses glass with a refractive index of 1.5.

Micro-Epsilon’s compatibility table lists the C2401 fiber family for this model. Choose length and construction for the controller, installation and cable motion.

The specified static resolution is obtained with averaging. For a moving process, check the dynamic resolution under its stated test conditions and the measuring rate of the chosen controller setup.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words