Measuring range 6 mm
Start of measuring range 63 mm
Linearity 1.2 µm
Light spot diameter 0.031 mm
Maximum measuring angle 10 deg
Numerical aperture (NA) 0.22
Storage temperature -20–70 °C
Operating temperature 5–70 °C
Weight 0.26 kg
Mounting Radial clamping (mounting adapter see accessories)
Technical specification details 6 mm net measuring range
Accuracy 1.8 µm
Minimum target thickness 0.3 mm
Target material reflective, diffuse as well as transparent surfaces (e.g. glass)
Linearity reference https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity.
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces EtherCAT
Interfaces Ethernet
Interfaces PROFINET
Number of measurement channels 1
Number of measurement channels 2
Outputs and interfaces Digital I/O
Outputs and interfaces Analog 0-10V
Outputs and interfaces RS422 / RS485
Outputs and interfaces 4-20mA
Protection class (DIN EN 60529) IP64
Protection class (DIN EN 60529) IP40
Resolution 0.017 µm
Resolution 0.19 µm
Sampling rate reference IFC2417: 25,000 measurements/s per synchronous channel
Sampling rate reference IFC2421MP: 10,000 measurements/s
Sampling rate reference IFC2465: 30,000 measurements/s
Sampling rate reference IFC2412: 8,000 measurements/s per synchronous channel
Sampling rate reference IFC2411: 8,000 measurements/s
Sampling rate reference IFC2466MP: 30,000 measurements/s per synchronous channel
Sampling rate reference IFC2416: 25,000 measurements/s
Sampling rate reference IFC2465MP: 30,000 measurements/s
Sampling rate reference IFC2421: 10,000 measurements/s
Sampling rate reference IFC2422MP: 10,000 measurements/s per synchronous channel
Sampling rate reference IFC2422: 10,000 measurements/s per synchronous channel
Sampling rate reference IFC2466: 30,000 measurements/s per synchronous channel
Request a quote for this product

Compatible system components

Controllers

  • IFC2411 Required
    Measuring rate
    8 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2411/IE Required
    Measuring rate
    8 kHz
    Communication
    RS422, PROFINET, EtherNet/IP, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412 Required
    Measuring rate
    8 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412/IE Required
    Measuring rate
    8 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2416 Required
    Measuring rate
    25 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417 Required
    Measuring rate
    25 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417/IE Required
    Measuring rate
    25 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421 Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, RS422, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421MP Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422 Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422MP Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465 Required
    Measuring rate
    30 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465MP Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, RS422, Ethernet
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466 Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466MP Required
    Measuring rate
    30 kHz
    Communication
    RS422, Ethernet, EtherCAT
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)

Compatible accessories

Optical fibres

Power supplies

Mounting

Accessories

Complementary products

Cables

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The measuring span is 6 mm and starts approximately 63 mm from the sensor face. Position the target so that the expected motion stays within the window.

The datasheet specifies less than 190 nm RMS noise at mid-span at a 1 kHz measuring rate. This value describes noise under the specified test conditions.

The datasheet lists 0.3 mm for glass with a refractive index of 1.5 under the specified test conditions. For a different material, verify that the controller can resolve the returns from both surfaces.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words