Skip to content

IFS2407-4HT/VAC

From the IFS2407 HT series

IFS2407 HT/VAC confocal heads for temperatures up to 200°C and vacuum down to UHV. Published measuring spans are 0.8, 2 and 4 mm.

Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for IFS2407-4HT/VAC
Measuring range 4 mm
Start of measuring range 14.5 mm
Light spot diameter 0.029 mm
Numerical aperture (NA) 0.19
Storage temperature -20–200 °C
Weight 0.04 kg
Mounting Clamping / screw connection via four mounting holes M2x0.4
Technical specification details 0-4 mm mapped range. Official vacuum-compatible sensor construction.
Accuracy 1.6 µm
Minimum target thickness 0.2 mm
Target material reflective, diffuse as well as transparent surfaces (e.g. glass)
Linearity reference Stored as the conservative published family/model accuracy for catalog filtering.
Sampling rate limited by system readout True
Sampling rate reference Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode.
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces Ethernet
Interfaces EtherCAT
Operating temperature 5–200 °C
Operating temperature 5–70 °C
Protection class (DIN EN 60529) IP64
Protection class (DIN EN 60529) IP40
Resolution 0.18 µm
Resolution 0.02 µm
Resolution 0.024 µm
Request a quote for this product

Compatible system components

Controllers

  • IFC2411 Required
    Measuring rate
    8 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2411/IE Required
    Measuring rate
    8 kHz
    Communication
    RS422, PROFINET, EtherNet/IP, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412 Required
    Measuring rate
    8 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412/IE Required
    Measuring rate
    8 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2416 Required
    Measuring rate
    25 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417 Required
    Measuring rate
    25 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417/IE Required
    Measuring rate
    25 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421 Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, RS422, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421MP Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422 Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422MP Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465 Required
    Measuring rate
    30 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465MP Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, RS422, Ethernet
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466 Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466MP Required
    Measuring rate
    30 kHz
    Communication
    RS422, Ethernet, EtherCAT
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)

Compatible accessories

Optical fibres

Power supplies

Accessories

Complementary products

Cables

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The measuring span is 4 mm and starts approximately 14.5 mm from the sensor face. Position the target so that the expected motion stays within the window.

The datasheet specifies less than 180 nm RMS noise at mid-span at a 1 kHz measuring rate. This value describes noise under the specified test conditions.

Micro-Epsilon rates the HT/VAC head for ambient temperatures up to 200°C. Verify the pressure and temperature limits of the fiber and feedthrough for the installation.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words