Skip to content

IFS2407-0.1(001)

From the IFS2407 series

Confocal heads with a small light spot and high numerical aperture for distance and roughness work. Selected models also support thickness measurement.

Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for IFS2407-0.1(001)
Measuring range 0.1 mm
Start of measuring range 1 mm
Light spot diameter 0.004 mm
Numerical aperture (NA) 0.7
Storage temperature -20–70 °C
Operating temperature 5–70 °C
Weight 0.036 kg
Mounting Radial clamping (mounting adapter see accessories)
Special features Light-intensive sensor
Technical specification details 0-0.1 mm mapped range. Official confocalDT sensor range.
Accuracy 0.04 µm
Minimum target thickness 0.005 mm
Target material reflective, diffuse as well as transparent surfaces (e.g. glass)
Sampling rate limited by system readout True
Linearity reference Stored as the conservative published family/model accuracy for catalog filtering.
Sampling rate reference Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode.
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces EtherCAT
Interfaces Ethernet
Protection class (DIN EN 60529) IP64
Protection class (DIN EN 60529) IP40
Protection class (DIN EN 60529) IP65
Resolution 0.006 µm
Resolution 0.001 µm
Resolution 0.003 µm
Request a quote for this product

Compatible system components

Controllers

  • IFC2411 Required
    Measuring rate
    8 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2411/IE Required
    Measuring rate
    8 kHz
    Communication
    RS422, PROFINET, EtherNet/IP, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412 Required
    Measuring rate
    8 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2412/IE Required
    Measuring rate
    8 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2416 Required
    Measuring rate
    25 kHz
    Communication
    Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417 Required
    Measuring rate
    25 kHz
    Communication
    RS422, Ethernet
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2417/IE Required
    Measuring rate
    25 kHz
    Communication
    EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421 Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, RS422, EtherCAT
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2421MP Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422 Required
    Measuring rate
    10 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2422MP Required
    Measuring rate
    10 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465 Required
    Measuring rate
    30 kHz
    Communication
    Ethernet, EtherCAT, RS422
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2465MP Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, RS422, Ethernet
    Inputs
    1
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466 Required
    Measuring rate
    30 kHz
    Communication
    EtherCAT, Ethernet, RS422
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)
  • IFC2466MP Required
    Measuring rate
    30 kHz
    Communication
    RS422, Ethernet, EtherCAT
    Inputs
    2
    Signal type
    Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet)

Compatible accessories

Optical fibres

Power supplies

Mounting

Accessories

Complementary products

Cables

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The measuring span is 0.1 mm and starts approximately 1 mm from the sensor face. Position the target so that the expected motion stays within the window.

The datasheet specifies less than 6 nm RMS noise at mid-span at a 1 kHz measuring rate. This value describes noise under the specified test conditions.

The specified light spot is 4 µm in diameter. For small features, make sure the spot remains on the measured area throughout its motion.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words