C2 Force
Diaphragm compression transducer for assembly-force and press monitoring. Output options include mV/V, voltage, current or IO-Link, depending on the version. Rated IP67.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-C2- — capacity: 500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN, 100 kN, 200 kN; output_signal: mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA), IO-Link; height_without_accessories: 1.18 in, 1.89 in, 2.36 in; diameter_without_cable_or_plug: 4.52755 in, 1.9685 in, 3.5433 in; constraints: [] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -20–60 °C |
|---|---|
| Interfaces | IO-Link |
| Force range | 0–50000 N |
| Protection class (DIN EN 60529) | IP67 |
| Numeric manufacturer accuracy class | 0.1–0.2 |
| ADC sampling rate | 450–40000 samples/s |
| Nominal force capacity | 500–200000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-C2/100KN | 1-C2/10KN | 1-C2/1KN | 1-C2/200KN | 1-C2/20KN | 1-C2/2KN | 1-C2/50KN | 1-C2/5KN | C2-100000N | C2-10000N | C2-1000N | C2-200000N | C2-20000N | C2-2000N | C2-50000N | C2-5000N | C2-500N | K-C2- · 1 kN | K-C2- · 10 kN | K-C2- · 100 kN | K-C2- · 2 kN | K-C2- · 20 kN | K-C2- · 200 kN | K-C2- · 5 kN | K-C2- · 50 kN | K-C2- · 500 N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only |
| Operating temperature | -20–60 °C | -30–85 °C | -20–60 °C | -20–60 °C | -20–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -20–60 °C | -20–60 °C | -10–60 °C | -30–85 °C | -10–60 °C | -30–85 °C | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | EtherCAT | Ethernet | Ethernet | Ethernet | EtherCAT | Ethernet | IO-Link | EtherCAT | EtherCAT | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Force range | 0–100000 N | 0–10000 N | 0–1000 N | 0–200000 N | 0–20000 N | 0–2000 N | 0–50000 N | 0–5000 N | 0–100000 N | 0–10000 N | 0–1000 N | 0–200000 N | 0–20000 N | 0–2000 N | 0–50000 N | 0–5000 N | 0–500 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Protection class (DIN EN 60529) | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 |
| Pressure sensor output | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | RS422 / RS485 | Digital I/O | Analog 0-10V | 4-20mA | RS422 / RS485 | RS422 / RS485 | Digital I/O | Digital I/O | Analog 0-10V | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Technical specification details | Maximum capacity (nominal load): 100 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 4.52755 in | Maximum capacity (nominal load): 10 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 1 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 200 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 4.52755 in | Maximum capacity (nominal load): 20 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 3.5433 in | Maximum capacity (nominal load): 2 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 50 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 3.5433 in | Maximum capacity (nominal load): 5 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | 100000 N rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression | 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression | 200000 N rated capacity = 200 kN (20.3943 t mass equivalent at standard gravity); compression | 20000 N rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression | 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression | 50000 N rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression | 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression | 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | DMP41 selectable result rate, intended for reference and calibration measurements | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | DMP41 selectable result rate, intended for reference and calibration measurements | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy class | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.2% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.1% | 0.2% |
| Numeric manufacturer accuracy class | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1111 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 450 samples/s | 1111 samples/s | 19200 samples/s | 450 samples/s | 1111 samples/s | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 kN nominal force capacity | 10 kN nominal force capacity | 100 kN nominal force capacity | 2 kN nominal force capacity | 20 kN nominal force capacity | 200 kN nominal force capacity | 5 kN nominal force capacity | 50 kN nominal force capacity | 500 N nominal force capacity |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000 N | 10000 N | 100000 N | 2000 N | 20000 N | 200000 N | 5000 N | 50000 N | 500 N |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-C2/100KN (opens in a new tab) | PDF — 1-C2/10KN (opens in a new tab) | PDF — 1-C2/1KN (opens in a new tab) | PDF — 1-C2/200KN (opens in a new tab) | PDF — 1-C2/20KN (opens in a new tab) | PDF — 1-C2/2KN (opens in a new tab) | PDF — 1-C2/50KN (opens in a new tab) | PDF — 1-C2/5KN (opens in a new tab) | PDF — C2-100000N (opens in a new tab) | PDF — C2-10000N (opens in a new tab) | PDF — C2-1000N (opens in a new tab) | PDF — C2-200000N (opens in a new tab) | PDF — C2-20000N (opens in a new tab) | PDF — C2-2000N (opens in a new tab) | PDF — C2-50000N (opens in a new tab) | PDF — C2-5000N (opens in a new tab) | PDF — C2-500N (opens in a new tab) | PDF — K-C2- · 1 kN (opens in a new tab) | PDF — K-C2- · 10 kN (opens in a new tab) | PDF — K-C2- · 100 kN (opens in a new tab) | PDF — K-C2- · 2 kN (opens in a new tab) | PDF — K-C2- · 20 kN (opens in a new tab) | PDF — K-C2- · 200 kN (opens in a new tab) | PDF — K-C2- · 5 kN (opens in a new tab) | PDF — K-C2- · 50 kN (opens in a new tab) | PDF — K-C2- · 500 N (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
C2 measures compressive force in static and dynamic applications. It is not specified as a tension/compression transducer.
No. Passive and integrated-amplifier versions include voltage, current or IO-Link options. The order code determines the output.
The C2 datasheet specifies IP67. Select suitable system connections and cabling.
No. TEDS is an ordering option; check the configuration code rather than assuming it is present.
The documented versions with and without an amplifier have the same external dimensions and accuracy class. The difference is a passive bridge versus an amplified output. The receiving system still needs the corresponding input type.
Get a quote or advice
Tell us what you need and an engineer will come back to you.