Diaphragm compression transducer for assembly-force and press monitoring. Output options include mV/V, voltage, current or IO-Link, depending on the version. Rated IP67.

Force range
0–5000 N
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for C2-5000N
Force range 0–5000 N
Accuracy class ⁦0.1%⁩
Accuracy (% FSO) 0.2 %
Protection class (DIN EN 60529) IP67
Technical specification details 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression
Ordering options and constraints K-C2- — capacity: 500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN, 100 kN, 200 kN; output_signal: mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA), IO-Link; height_without_accessories: 1.18 in, 1.89 in, 2.36 in; diameter_without_cable_or_plug: 4.52755 in, 1.9685 in, 3.5433 in; constraints: []
Load mode Compression only

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

ADC sampling rate 450 samples/s
ADC sampling rate 1111 samples/s
ADC sampling rate 19200 samples/s
ADC sampling rate 40000 samples/s
Interfaces EtherCAT
Interfaces PROFINET
Interfaces Ethernet
Interfaces IO-Link
Operating temperature -10–60 °C
Operating temperature -20–60 °C
Operating temperature -30–85 °C
Outputs and interfaces Digital I/O
Outputs and interfaces 4-20mA
Outputs and interfaces Analog 0-10V
Outputs and interfaces RS422 / RS485
Sampling rate reference The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted
Sampling rate reference 0.9 ms minimum IO-Link process-data cycle; the sensor electronics sample internally at 40 kHz
Sampling rate reference DMP41 selectable result rate, intended for reference and calibration measurements
Sampling rate reference ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
Sampling rate reference MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth