C6B Force
Column-type compression force transducer for high loads. Selected versions have a central bore. Fixed cable, connector and TEDS options depend on configuration.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-C6B — capacity: 200 kN, 500 kN, 1 MN, 2 MN, 5 MN, 10 MN; output_signal: mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA); mechanical_interfaces: Hole through type, Column type; height_without_accessories: 2.36 in, 3.94 in, 7.09 in, 9.45 in; diameter_without_cable_or_plug: 6.25983 in, 3.1496 in; constraints: [] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–500000 N |
|---|---|
| Nominal force capacity | 200000–10000000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-C6B/10MN | 1-C6B/1MN | 1-C6B/200KN | 1-C6B/2MN | 1-C6B/500KN | 1-C6B/5MN | K-C6B · 1 MN | K-C6B · 10 MN | K-C6B · 2 MN | K-C6B · 200 kN | K-C6B · 5 MN | K-C6B · 500 kN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only | Compression only |
| Force range | 0–10000000 N | 0–1000000 N | 0–200000 N | 0–2000000 N | 0–500000 N | 0–5000000 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Pressure sensor output | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Technical specification details | Maximum capacity (nominal load): 10 MN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Column type; Height (without accessories): 9.45 in; Diameter (without cable or plug): 10.51179 in | Maximum capacity (nominal load): 1 MN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 3.94 in; Diameter (without cable or plug): 7.44093 in | Maximum capacity (nominal load): 200 kN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 2.36 in; Diameter (without cable or plug): 1.358265 in | Maximum capacity (nominal load): 2 MN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 3.94 in; Diameter (without cable or plug): 1.594485 in | Maximum capacity (nominal load): 500 kN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 2.36 in; Diameter (without cable or plug): 0.570865 in | Maximum capacity (nominal load): 5 MN; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Column type; Height (without accessories): 7.09 in; Diameter (without cable or plug): 7.44093 in | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate limited by system readout | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy class | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% |
| Numeric manufacturer accuracy class | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 MN nominal force capacity | 10 MN nominal force capacity | 2 MN nominal force capacity | 200 kN nominal force capacity | 5 MN nominal force capacity | 500 kN nominal force capacity |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000000 N | 10000000 N | 2000000 N | 200000 N | 5000000 N | 500000 N |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-C6B/10MN (opens in a new tab) | PDF — 1-C6B/1MN (opens in a new tab) | PDF — 1-C6B/200KN (opens in a new tab) | PDF — 1-C6B/2MN (opens in a new tab) | PDF — 1-C6B/500KN (opens in a new tab) | PDF — 1-C6B/5MN (opens in a new tab) | PDF — K-C6B · 1 MN (opens in a new tab) | PDF — K-C6B · 10 MN (opens in a new tab) | PDF — K-C6B · 2 MN (opens in a new tab) | PDF — K-C6B · 200 kN (opens in a new tab) | PDF — K-C6B · 5 MN (opens in a new tab) | PDF — K-C6B · 500 kN (opens in a new tab) |
Compatible accessories
Cables
-
K-CAB-F-B
Only for source configuration configuration-29b77d7d94063a97973d9fe6: K-C6B · 10 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
-
K-CAB-F-G
Only for source configuration configuration-29b77d7d94063a97973d9fe6: K-C6B · 10 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
-
K-CAB-F-L
Only for source configuration configuration-29b77d7d94063a97973d9fe6: K-C6B · 10 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
C6B is designed for compression. Selection includes nominal force and suitable force-introduction accessories, not just transducer dimensions.
No. The table specifies IP68 for fixed cable, IP67 for the bayonet-connector option when connected, and IP64 for the threaded-connector option. The stated IP68 test is a 1 m water column for 100 hours.
Yes. The table separates hardened compression plates, the ZL load button and ZK spherical cap. Use the value for the mounting arrangement rather than assigning the best value to every model.
The datasheet separates the transducer without an integrated amplifier from amplified configurations. Select the order code and acquisition electronics for the actual signal path.
No. Natural frequency is a mechanical property that varies with capacity. Sampling rate also depends on the amplifier and DAQ. Do not present natural frequency as system sampling rate.