- Pressure range
- 0–1000 bar
1-P2VA1/1000BAR
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
Product categories
Laser triangulation
Capacitive
Inductive (eddy current)
Laser time-of-flight (TOF)
Draw-wire sensors
LVDT
Magnetic
Confocal chromatic
Interferometers
Colour & gloss measurement
Temperature sensors
Force
Weight
Torque
Noise & sound
Pressure sensors
Strain
Angle
Light intensity & surface quality
3D sensors
Confocal line scanners
Thickness measurement
Optical micrometers
Rotational speed
Laser scanners (2D/3D profile sensors)
Length measurement
Vibration and acceleration sensors
Shakers (vibration exciters)
Vibration controllers
Vibration calibrators
Software
Data acquisition
Accessories
Micro-Epsilon
Sensors and measuring systems from Germany
Qlar
Qlar (formerly Schenck Process) – weighing, feeding and flow measurement for bulk materials
Optocraft
Measuring systems for optics and lasers
Brüel & Kjær Vibro
Vibration monitoring for rotating equipment
Elovis
Non-contact systems for length and speed measurement
HBK
Load cells, strain gauges and data acquisition
HORIBA
Analytical instruments, emissions and flow control
Solutions
Sensors
Explore pressure sensors and transducers. Compare measuring ranges and model specifications for industrial measurement and test applications.
Showing HBK products only. Show all manufacturers
101 matching models
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P2VA series
Absolute pressure transducers with integrated amplification. P2VA1 provides voltage output and P2VA2 provides current output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
From the P3IC series
P3IC and P3ICP absolute pressure transducers for static and dynamic measurements up to 3,000 bar, with a temperature sensor and passive bridge output.
Certified quality management, calibration certificates and calibration services at manufacturers’ facilities.
Answers to the most common questions about our products and services
Specify the pressure reference. For example, the P3 transducers described in the manual measure absolute pressure using a sealed reference chamber. Electronically taring atmospheric pressure can support gauge measurement under defined conditions, but the two definitions should not be interchanged without checking the application.
A short peak duration does not by itself permit an overload. Check the model static and dynamic loading limits. For P3, for example, dynamic pressure peaks are limited to nominal pressure and a separate peak-to-peak fluctuation limit applies. This is a model limit, not a universal percentage for pressure sensors.
A bridge output requires a measuring amplifier matched to transducer excitation and sensitivity. A voltage- or current-output transmitter requires a compatible input for that conditioned signal. The HBK catalogue contains different configurations, so check the selected model and option before defining a direct system connection.
Not necessarily. P3 tables list accuracy data by range and configuration, together with repeatability and temperature effects. Check the definition and reference conditions for each value. Do not copy a single accuracy value to every model in the series or substitute repeatability for accuracy class.
Check nominal temperature range, operating temperature range and the configuration IP rating separately. The HBK catalogue also shows differences in electrical connections. Do not infer that one model IP rating applies to an entire series or every possible connection.
Trapped volumes and gas or liquid volumes on the application side can alter the measurement. The P3 manual provides installation guidance to prevent an air cushion during dynamic liquid-pressure measurement. Also check the frequency range against transducer resonance, where amplitude amplification can occur.
Tell us what you need to measure and an engineer will get back to you.