Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of PW4M
Force range 0–29.41995 N

Models in the series

One column per model: what differs between the models of the series.

Models of PW4M compared by parameter
Parameter 1-PW4C3/2KG-1 1-PW4C3/300G-1 1-PW4C3/3KG-1 1-PW4C3/500G-1 1-PW4MC3/1KG-1 1-PW4MC3/2KG-1 1-PW4MC3/300G-1 1-PW4MC3/3KG-1 1-PW4MC3/500G-1 1-PW4MC3/5KG-1
Technical specification details Maximum capacity: 4.41 lb; Minimum verification interval (Vmin): 0.2 g Maximum capacity: 0.66 lb; Minimum verification interval (Vmin): 50 g Maximum capacity: 6.61 lb; Minimum verification interval (Vmin): 0.5 g Maximum capacity: 1.1 lb; Minimum verification interval (Vmin): 0.1 g Maximum capacity: 2.2 lb; Minimum verification interval (Vmin): 0.2 g Maximum capacity: 4.41 lb; Minimum verification interval (Vmin): 0.2 g Maximum capacity: 0.66 lb; Minimum verification interval (Vmin): 50 g Maximum capacity: 6.61 lb; Minimum verification interval (Vmin): 0.5 g Maximum capacity: 1.1 lb; Minimum verification interval (Vmin): 0.1 g Maximum capacity: 11.02 lb; Minimum verification interval (Vmin): 1 g
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Force range 0–19.6133 N Not specified 0–29.41995 N Not specified 0–9.80665 N Not specified Not specified Not specified Not specified 0–49.03325 N
Force range Not specified Not specified Not specified Not specified Not specified 0–19.6133 N Not specified 0–29.41995 N Not specified Not specified
Sampling rate reference Not specified Not specified Not specified Not specified Not specified The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. Not specified
Sampling rate limited by system readout Not specified Not specified Not specified Not specified Not specified True True True True Not specified
Linearity reference Not specified Not specified Not specified Not specified Not specified No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. No single accuracy class is inferred when it is not shown for the exact ordering code. Not specified
Repeatability reference Not specified Not specified Not specified Not specified Not specified Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified
Accuracy class Not specified Not specified Not specified Not specified Not specified C3 C3 C3 C3 Not specified
Status Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 1-PW4C3/2KG-1 (opens in a new tab) PDF — 1-PW4C3/300G-1 (opens in a new tab) PDF — 1-PW4C3/3KG-1 (opens in a new tab) PDF — 1-PW4C3/500G-1 (opens in a new tab) PDF — 1-PW4MC3/1KG-1 (opens in a new tab) PDF — 1-PW4MC3/2KG-1 (opens in a new tab) PDF — 1-PW4MC3/300G-1 (opens in a new tab) PDF — 1-PW4MC3/3KG-1 (opens in a new tab) PDF — 1-PW4MC3/500G-1 (opens in a new tab) PDF — 1-PW4MC3/5KG-1 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

300 and 500 g, 2 and 3 kg.

200×200 mm.

As a shielded four-wire analogue bridge.

IP65.

1.3 N·m for the specified M3 class 8.8 screws.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words