U10F-250kN
From the U10F series
Low-profile strain-gauge transducer for compression and tension, including cyclic loads. Available with mV/V or integrated IO-Link. Ingress protection depends on the connector or cable, up to IP68 with the cable option.
- Force range
- -250000–250000 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | -250000–250000 N |
|---|---|
| Accuracy class | 0.04% |
| Technical specification details | 250 kN rated capacity = 250 kN (25.4929 t mass equivalent at standard gravity); compression and tension |
| Ordering options and constraints | K-U10F — capacity: 50 kN, 125 kN, 250 kN, 500 kN, 1.25 MN; output_signal: mV/V (passive strain gauge), IO-Link; height_without_accessories: 1.75 in, 2.5 in, 3.5 in, 5 in; diameter_without_cable_or_plug: 15.3543 in, 6.059043 in, 7.999984 in, 10.98423 in; constraints: [] |
| Load mode | Compression and tension |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| ADC sampling rate | 450 samples/s |
|---|---|
| ADC sampling rate | 40000 samples/s |
| ADC sampling rate | 19200 samples/s |
| Interfaces | Ethernet |
| Interfaces | EtherCAT |
| Interfaces | PROFINET |
| Outputs and interfaces | Digital I/O |
| Outputs and interfaces | RS422 / RS485 |
| Outputs and interfaces | Analog 0-10V |
| Sampling rate reference | DMP41 selectable result rate, intended for reference and calibration measurements |
| Sampling rate reference | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| Sampling rate reference | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.