U10F Force
Low-profile strain-gauge transducer for compression and tension, including cyclic loads. Available with mV/V or integrated IO-Link. Ingress protection depends on the connector or cable, up to IP68 with the cable option.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-U10F — capacity: 50 kN, 125 kN, 250 kN, 500 kN, 1.25 MN; output_signal: mV/V (passive strain gauge), IO-Link; height_without_accessories: 1.75 in, 2.5 in, 3.5 in, 5 in; diameter_without_cable_or_plug: 15.3543 in, 6.059043 in, 7.999984 in, 10.98423 in; constraints: [] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Interfaces | IO-Link |
|---|---|
| Force range | 0–1250000 N |
| ADC sampling rate | 40000 samples/s |
| Numeric manufacturer accuracy class | 0.04–0.05 |
| Nominal force capacity | 50000–1250000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-U10F/1.25MN | 1-U10F/125KN | 1-U10F/250KN | 1-U10F/500KN | 1-U10F/50KN | K-U10F · 1.25 MN | K-U10F · 125 kN | K-U10F · 250 kN | K-U10F · 50 kN | K-U10F · 500 kN | U10F-1250kN | U10F-125kN | U10F-250kN | U10F-500kN | U10F-50kN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Ethernet | EtherCAT | Ethernet | Ethernet | Ethernet |
| Force range | 0–1250000 N | 0–125000 N | 0–250000 N | 0–500000 N | 0–50000 N | Not specified | Not specified | Not specified | Not specified | Not specified | -1250000–1250000 N | -125000–125000 N | -250000–250000 N | -500000–500000 N | -50000–50000 N |
| ADC sampling rate | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | Not specified | Not specified | Not specified | Not specified | Not specified | 450 samples/s | 19200 samples/s | 450 samples/s | 40000 samples/s | 40000 samples/s |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | Not specified | Not specified | Not specified | Not specified | Not specified | DMP41 selectable result rate, intended for reference and calibration measurements | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements | DMP41 selectable result rate, intended for reference and calibration measurements | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Not specified | Not specified | Not specified | Not specified | Not specified | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Analog 0-10V |
| Technical specification details | Maximum capacity (nominal load): 1.25 MN; Output signal: mV/V (passive strain gauge); Height (without accessories): 5 in; Diameter (without cable or plug): 15.3543 in | Maximum capacity (nominal load): 125 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.75 in; Diameter (without cable or plug): 6.059043 in | Maximum capacity (nominal load): 250 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.5 in; Diameter (without cable or plug): 7.999984 in | Maximum capacity (nominal load): 500 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 3.5 in; Diameter (without cable or plug): 10.98423 in | Maximum capacity (nominal load): 50 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.75 in; Diameter (without cable or plug): 6.059043 in | Not specified | Not specified | Not specified | Not specified | Not specified | 1250 kN rated capacity = 1,250 kN (127.4645 t mass equivalent at standard gravity); compression and tension | 125 kN rated capacity = 125 kN (12.7465 t mass equivalent at standard gravity); compression and tension | 250 kN rated capacity = 250 kN (25.4929 t mass equivalent at standard gravity); compression and tension | 500 kN rated capacity = 500 kN (50.9858 t mass equivalent at standard gravity); compression and tension | 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression and tension |
| Sampling rate limited by system readout | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Pressure sensor output | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy class | 0.05% | 0.04% | 0.04% | 0.05% | 0.04% | 0.05% | 0.04% | 0.04% | 0.04% | 0.05% | 0.05% | 0.04% | 0.04% | 0.05% | 0.04% |
| Numeric manufacturer accuracy class | 0.05 | 0.04 | 0.04 | 0.05 | 0.04 | 0.05 | 0.04 | 0.04 | 0.04 | 0.05 | 0.05 | 0.04 | 0.04 | 0.05 | 0.04 |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | 1.25 MN nominal force capacity | 125 kN nominal force capacity | 250 kN nominal force capacity | 50 kN nominal force capacity | 500 kN nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | 1250000 N | 125000 N | 250000 N | 50000 N | 500000 N | Not specified | Not specified | Not specified | Not specified | Not specified |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-U10F/1.25MN (opens in a new tab) | PDF — 1-U10F/125KN (opens in a new tab) | PDF — 1-U10F/250KN (opens in a new tab) | PDF — 1-U10F/500KN (opens in a new tab) | PDF — 1-U10F/50KN (opens in a new tab) | PDF — K-U10F · 1.25 MN (opens in a new tab) | PDF — K-U10F · 125 kN (opens in a new tab) | PDF — K-U10F · 250 kN (opens in a new tab) | PDF — K-U10F · 50 kN (opens in a new tab) | PDF — K-U10F · 500 kN (opens in a new tab) | PDF — U10F-1250kN (opens in a new tab) | PDF — U10F-125kN (opens in a new tab) | PDF — U10F-250kN (opens in a new tab) | PDF — U10F-500kN (opens in a new tab) | PDF — U10F-50kN (opens in a new tab) |
Compatible accessories
Cables
-
K-CAB-F-B
Only for source configuration configuration-1a23b6e5c3190fb98cd41f04: K-U10F · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
-
K-CAB-F-L
Only for source configuration configuration-1a23b6e5c3190fb98cd41f04: K-U10F · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Yes. U10F supports tension/compression and static/dynamic measurements. Respect the load limits of the selected configuration.
U10F has flange connections on both sides. Select the manufacturer’s mounting screw kit and tightening instructions for the model.
No. The stated linearity is 0.035%–0.05%, depending on capacity. Compare the exact model.
The datasheet lists an integrated IO-Link amplifier option alongside passive mV/V versions.
No. The passive version documents a bridge connection with excitation, signal and sense leads. VAIO documents an IO-Link Class A connector with supply and data. Select the cable and receiving input for the ordered version, not just the series name.
Get a quote or advice
Tell us what you need and an engineer will come back to you.