U9C Force
Miniature strain-gauge transducer for compression and tension. Rated IP67. Options include passive mV/V or an inline amplifier with voltage, current or IO-Link.
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-U9C — capacity: 50 N, 100 N, 200 N, 0.5 kN, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN; cable_length: 1.5 m, 3 m, 5 m, 6 m, 7 m, 12 m; output: mV/V, 0…10 V, 4…20 mA, IO-Link, VA1, VA2, VAIO; connector: Y, F, Q, N, M, M12; teds: Not selected, T; mechanical_interface: Both sides central external thread; constraints: [{"when": {"output": ["VA1", "VA2", "VAIO"]}, "allow": {"cable_length": ["1.5 m", "3 m"]}, "reason": "HBK limits inline-amplifier variants to the documented short cable lengths."}, {"when": {"teds": "T"}, "deny": {"connector": "M12", "output": ["VA1", "VA2", "VAIO"]}, "reason": "TEDS is available with plug variants, not free-end/M12 or inline-amplifier variants."}] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | 0–5000 N |
|---|---|
| Interfaces | IO-Link |
| Nominal force capacity | 50–50000 N |
| ADC sampling rate | 450–40000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-U9C/0.5KN | 1-U9C/100N | 1-U9C/10KN | 1-U9C/1KN | 1-U9C/200N | 1-U9C/20KN | 1-U9C/2KN | 1-U9C/50KN | 1-U9C/50N | 1-U9C/5KN | K-U9C · 1 kN | K-U9C · 10 kN | K-U9C · 100 N | K-U9C · 2 kN | K-U9C · 20 kN | K-U9C · 200 N | K-U9C · 5 kN | K-U9C · 50 kN | K-U9C · 50 N | K-U9C · 500 N | U9C | U9C-10000N | U9C-1000N | U9C-100N | U9C-20000N | U9C-2000N | U9C-200N | U9C-50000N | U9C-5000N | U9C-500N | U9C-50N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Load mode | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension | Compression and tension |
| Protection class (DIN EN 60529) | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 |
| Force range | 0–500 N | 0–100 N | -10000–10000 N | -1000–1000 N | -200–200 N | 0–20000 N | -2000–2000 N | -50000–50000 N | -50–50 N | -5000–5000 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | -50000–50000 N | -10000–10000 N | -1000–1000 N | -100–100 N | -20000–20000 N | -2000–2000 N | -200–200 N | -50000–50000 N | -5000–5000 N | -500–500 N | -50–50 N |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Ethernet | PROFINET | Ethernet | Ethernet | Ethernet | Ethernet | EtherCAT | PROFINET | PROFINET | EtherCAT | Ethernet |
| Technical specification details | Maximum capacity (nominal load): 500 N; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.75 in; Diameter (without cable or plug): 1.02362 in | Maximum capacity (nominal load): 100 N; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.65 in; Diameter (without cable or plug): 0.70866 in | Maximum capacity (nominal load): 10 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 1.02362 in | Maximum capacity (nominal load): 1 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.75 in; Diameter (without cable or plug): 1.02362 in | Maximum capacity (nominal load): 200 N; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.65 in; Diameter (without cable or plug): 0.70866 in | Maximum capacity (nominal load): 20 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 1.02362 in | Maximum capacity (nominal load): 2 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 1.02362 in | Maximum capacity (nominal load): 50 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 3.31 in; Diameter (without cable or plug): 1.81102 in | Maximum capacity (nominal load): 50 N; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.65 in; Diameter (without cable or plug): 1.81102 in | Maximum capacity (nominal load): 5 kN; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 1.02362 in | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Select nominal force by U9C variant | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression and tension | 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression and tension | 100 N rated capacity = 100 N (10.1972 kg mass equivalent at standard gravity); compression and tension | 20000 N rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression and tension | 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression and tension | 200 N rated capacity = 200 N (20.3943 kg mass equivalent at standard gravity); compression and tension | 50000 N rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression and tension | 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression and tension | 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression and tension | 50 N rated capacity = 50 N (5.0986 kg mass equivalent at standard gravity); compression and tension |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Analog 0-10V | Analog 0-10V | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | Analog 0-10V | Analog 0-10V | Digital I/O | Analog 0-10V | Analog 0-10V | RS422 / RS485 |
| Sampling rate reference | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | DMP41 selectable result rate, intended for reference and calibration measurements | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements |
| Sampling rate limited by system readout | True | True | True | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Linearity reference | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Pressure sensor output | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy class | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | Not specified | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% | 0.2% |
| Numeric manufacturer accuracy class | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | Not specified | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 kN nominal force capacity | 10 kN nominal force capacity | 100 N nominal force capacity | 2 kN nominal force capacity | 20 kN nominal force capacity | 200 N nominal force capacity | 5 kN nominal force capacity | 50 kN nominal force capacity | 50 N nominal force capacity | 500 N nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000 N | 10000 N | 100 N | 2000 N | 20000 N | 200 N | 5000 N | 50000 N | 50 N | 500 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1200 samples/s | 19200 samples/s | 40000 samples/s | 450 samples/s | 40000 samples/s | 19200 samples/s | 19200 samples/s | 40000 samples/s | 450 samples/s | 19200 samples/s | 40000 samples/s |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % |
| Operating temperature | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | -30–85 °C | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 1-U9C/0.5KN (opens in a new tab) | PDF — 1-U9C/100N (opens in a new tab) | PDF — 1-U9C/10KN (opens in a new tab) | PDF — 1-U9C/1KN (opens in a new tab) | PDF — 1-U9C/200N (opens in a new tab) | PDF — 1-U9C/20KN (opens in a new tab) | PDF — 1-U9C/2KN (opens in a new tab) | PDF — 1-U9C/50KN (opens in a new tab) | PDF — 1-U9C/50N (opens in a new tab) | PDF — 1-U9C/5KN (opens in a new tab) | PDF — K-U9C · 1 kN (opens in a new tab) | PDF — K-U9C · 10 kN (opens in a new tab) | PDF — K-U9C · 100 N (opens in a new tab) | PDF — K-U9C · 2 kN (opens in a new tab) | PDF — K-U9C · 20 kN (opens in a new tab) | PDF — K-U9C · 200 N (opens in a new tab) | PDF — K-U9C · 5 kN (opens in a new tab) | PDF — K-U9C · 50 kN (opens in a new tab) | PDF — K-U9C · 50 N (opens in a new tab) | PDF — K-U9C · 500 N (opens in a new tab) | PDF — U9C (opens in a new tab) | PDF — U9C-10000N (opens in a new tab) | PDF — U9C-1000N (opens in a new tab) | PDF — U9C-100N (opens in a new tab) | PDF — U9C-20000N (opens in a new tab) | PDF — U9C-2000N (opens in a new tab) | PDF — U9C-200N (opens in a new tab) | PDF — U9C-50000N (opens in a new tab) | PDF — U9C-5000N (opens in a new tab) | PDF — U9C-500N (opens in a new tab) | PDF — U9C-50N (opens in a new tab) |
Compatible accessories
Cables
-
1-KAB168-5
Only for source configuration configuration-0b3c45c83b1c82cb7ec049ae: K-U9C · 50 kN configuration; selected configuration must be matched before display.; For the VA1 voltage or VA2 current inline amplifier, not a passive bridge or 4-pin VAIO IO-Link port. This is the amplifier-output cable, separate from the factory sensor-to-amplifier lead.
-
1-KAB168-20
Only for source configuration configuration-0b3c45c83b1c82cb7ec049ae: K-U9C · 50 kN configuration; selected configuration must be matched before display.; For the VA1 voltage or VA2 current inline amplifier, not a passive bridge or 4-pin VAIO IO-Link port. This is the amplifier-output cable, separate from the factory sensor-to-amplifier lead.
Mounting
-
1-Z8/100kg/ZGW
Only for source configuration configuration-15baabd39101a13d80286f25: K-U9C · 1 kN configuration; selected configuration must be matched before display.; Match rated force and thread, and verify permissible alignment and load introduction. Not a compression thrust piece.
-
1-U9/20kN/ZGWR
Only for source configuration configuration-4f34f08eae26369ac08d370a: K-U9C · 20 kN configuration; selected configuration must be matched before display.; Match rated force and thread, and verify permissible alignment and load introduction. Not a compression thrust piece.
-
1-U9a/50kN/ZGW
Only for source configuration configuration-0b3c45c83b1c82cb7ec049ae: K-U9C · 50 kN configuration; selected configuration must be matched before display.; Match rated force and thread, and verify permissible alignment and load introduction. Not a compression thrust piece.
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Yes. HBM specifies U9C for tensile and compressive force measurement. Select the rated capacity and configuration for the application.
No. The series has different configurations: passive mV/V, amplified 0–10 V or 4–20 mA, and an optional IO-Link version. Select the configuration for the acquisition or control system.
The datasheet specifies IP67 for the transducer. Check the selected connector, amplifier and system connections separately.
No. Dimensions and threads vary with nominal force. For example, the 2–20 kN group uses M10, while the 50 kN version uses M16×1.5.
No. It is the transducer’s accuracy class. The table separately specifies linearity, repeatability, hysteresis and temperature effects. Amplifier and installation contributions also matter.